Download Print this page
Fronius Galvo Quick Start Manual

Fronius Galvo Quick Start Manual

Energy management function of fronius datamanager 2.0

Advertisement

Quick Links

Energy Management Function
Of Fronius Datamanager 2.0
* Included in Fronius Galvo / Primo / Symo / Eco
Version 1.0, Training and Education, PH
2016, Fronius International GmbH

Advertisement

loading

Summary of Contents for Fronius Galvo

  • Page 1 Energy Management Function Of Fronius Datamanager 2.0 * Included in Fronius Galvo / Primo / Symo / Eco Version 1.0, Training and Education, PH 2016, Fronius International GmbH...
  • Page 2: General Information

    “divert” to a load instead of exporting it to the grid. The Fronius Datamanager comes built-in in the inverter series Fronius Galvo, Primo, Symo, Eco and can be retrofitted to Fronius IG, IG Plus, and CL. The Fronius Datamanager is available as card or box.
  • Page 3: Wiring Detail

    1.1.2 Switching loads via external relay without energy meter The digital output signal of the Datamanager controls an external relay, which switches the load. The threshold to switch ON/OFF can be set accordingly to the output power of the inverter. Fronius inverter with Datamanager Ext. Relay...
  • Page 4 Fronius Datamanger Version 2.0 was built-in in Fronius Galvo and Symo inverters until end of 2014. Inverters with a serial number 25490000 and higher are equipped with version 2.0. It is built-in in all Fronius Primo and Eco units.
  • Page 5 1. Activate Energy Management function by selecting “Controlling: by power production”. If a Fronius Smart Meter is included in the system, the setting “by power surplus (in case of feed-in limits)” can be chosen. The treshholds to switch ON/OFF are then activated according to site surplus energy.
  • Page 6: Remote Control

    Chose the ON/OFF threshold either a value for ‘Feed in’ or ‘Consumption’***. Figure 7 - Datamanager web interface when using an energy meter 3.2.2 Datamanger software version 3.2.2 or smaller Note: Datamanager software version 3.2.2 and smaller have less features. To get the full functionality make a software update as described in chapter 5.2 Software Update of Datamanager.
  • Page 7 (via Wi-Fi of Datamanager 2.0 only) http://datamanager/ Alternatively you can use Fronius Solar.Web App for tablet or smart phone and go to ‘Settings’ and click ‘PV Inverter Homepage’ 5.3 Software update for Fronius Datamanager / Go to Datamanager web interface as described in 5.2 Datamanager web interface / Select Firmware update on the right hand side of the Datamanager web interface (also called PV Inverter Homepage) and follow the steps shown in the pictures below.
  • Page 8 +43 (0) 7242 241- 5670 Fronius reserves all rights, in particular rights of reproduction, distribution and translation. No part of this work may be reproduced in any way without the written consent of Fronius. It must not be saved, edited, reproduced or distributed using any electrical or electronic system.

This manual is also suitable for:

PrimoSymoEco