2. WIRING
2.3

Unit Interconnection

The transponder unit (FA-1701), monitor unit (FA-1702) and the pilot plug unit (FA-
1703) use different connectors for interconnection. See the figures below to fabricate
the connections.
How to attach wires to the connectors
Transponder unit FA-1701
Terminal opener is located on rear of the FA-1701 cover.
Wire
Twist
Monitor unit FA-1702
Terminal opener is located inside cable clamp (rear cover).
Push downward.
Wire
Pilot plug unit FA-1703
Use a flat head screwdriver to open the terminals.
Wire
Twist
2-4
Terminal
opener
Procedure
1. Twist core.
Push
Push
2. Insert terminal opener and push.
3. Insert wire into hole. Be careful not to pinch the sheath.
4. Release terminal opener.
5. Pull wire to confirm it is correctly inserted.
WAGO connector
Terminal opener
WAGO connector
Twist
Push downward.
Procedure
1. Twist core.
2. Using a flat screw driver, push the terminal opener.
3. Insert wire into hole. Be careful not to pinch the sheath.
4. Release terminal opener.
5. Pull wire to confirm it is correctly inserted.
SATO PARTS connector
Procedure
1. Twist the cores.
2. Push the terminal opener downward.
3. Insert the wire to hole.
4. Remove the terminal opener.
5. Pull the wire to confirm that it is secure.