1. MOUNTING
1.2.1
How to fit the optional waterproofing kit (OP05-139)
The optional waterproofing kit must be fitted at the same time as the cabling is con-
nected to the FA-1702. The kit contains the following items:
• Cover gasket (Code:100-403-800-10) 1
• Cable gasket (Code:100-403-791-10) 1
1. Unfasten the four screws on the rear cable clamp, then remove the cable clamp
to reveal the WAGO connector.
2. Fit the cable gasket to the cable clamp, referring to the figure below.
1. Fit the cable gasket to the cable clamp,
passing the fixing lip partially through
the cable clamp.
Cable clamp
3. Check that the cable gasket is flush
against the cable clamp, as shown
below.
3. Pass the cabling through the cable gasket and cable clamp.
Note: To maintain the IPx5 waterproof rating, the cable must be TTYCSLA-4 (or
equivalent) with a diameter of 14.4±0.4 mm.
4. Fit the cover gasket to the rear of the FA-1702. Make sure the cover gasket is
placed inside the groove indicated in the figure below.
5. Connect the cabling to the FA-1702, referring to section 2.3.1.
6. Slide the cable clamp along the cable until the clamp is flush against the rear of
the FA-1702.
Note: The cable clamp must be oriented with the
dome-side up, to prevent water intrusion.
7. Fasten the four screws removed at step 1.
8. Secure the cabling to the cable clamp with cable ties
(included) referring to the figure in section 2.3.1.
1-8
Fixing lip
Cable gasket
2. To pass the fixing lip completely
through the cable gasket, twist the
cable gasket gently.
4. Check that the cable gasket's fixing lip
is flush against the inside of the cable
clamp.
WAGO lever
Fixing lip
Groove for
Groove for
cover gasket
cover gasket
Dome
Cable
Cable
clamp
clamp