  • Page 1 EL1SS Telephone Entry System Installation and Programming Manual For more information, please visit www.devancocanada.com or call toll free at 855-931-3334...
  • Page 2: Table Of Contents

    Wiring a Gate Operator (Normally Open) ......7 REPAIR PARTS ........21 Wiring an Auto-Call Sensor ..........7 Wiring a Gate Operator (Normally Open) EL1SS MASTER CODE ......21 and a Door Strike Lock (Normally Open) ......8 Wiring a Gate Operator (Normally Open) WARRANTY ........22 and a Maglock (Normally Closed) ........
  • Page 3: Introduction

    INTRODUCTION INSTALLATION TESTING PROGRAMMING CABLE REQUIREMENTS Outdoor installations require shielded cable. Non-shielded cable can be used for indoor installations ONLY. PROCESSOR BOARD WIRE TYPE RECOMMENDATIONS From the power transformer at 120 Vac outlet 2 - Conductor Cable Shielded Only - See Power Wire Table Below From the door strike, maglock or gate operator 2 - Conductor Cable See device specifications for wire size...
  • Page 4: Carton Inventory

    INTRODUCTION INSTALLATION TESTING PROGRAMMING CARTON INVENTORY Unit (1) Key (1) 12 Vac 20 VA or 16 Vdc 2.5A Plug-In UL Listed Power Transformer (1) Bypass Board (1) Manual (1) DESCRIPTION OF THE PROCESSOR BOARD Autocall Input: Connector for accessory device to trigger Tamper Switch home dialing.
  • Page 5: Mount The Unit

    INTRODUCTION INSTALLATION TESTING PROGRAMMING MOUNT THE UNIT Accessories: Optional method to mount. 1. Choose the mounting location for the unit. LiftMaster Gooseneck Pedestal Post Models Unlock faceplate and open. PED42 or PED64 Mark holes and pre-drill holes. 4. Mount to a solid surface or post (hardware not provided). Wall Mount Pedestal Mount OVERVIEW OF TELCO WIRING...
  • Page 6: Typical Telco Overview With The Unit

    RING RING Phone lines with DSL service. In order for the EL1SS to function normally a DSL filter is required to separate the DSL (digital) signal from the telephone service (POTS). 1. Install the splitter between the demarcation box and the EL1SS.
  • Page 7: Wiring The Unit With A Telco Line

    INTRODUCTION INSTALLATION TESTING PROGRAMMING Never run data wires and high voltage wires in the same conduit. The high voltage wires may interfere with the data wires and cause the system to malfunction. WIRING THE UNIT WITH A TELCO LINE Telco Entrance Box Demarcation Point Ringer Equivalence Number (REN) = 4 Bypass Board...
  • Page 8: Wiring A Gate Operator (Normally Open)

    INTRODUCTION INSTALLATION TESTING PROGRAMMING WIRING A GATE OPERATOR (NORMALLY OPEN) The gate operator can be connected to Relay 1 or Relay 2. See the Programming section for information about configuring Relays 1 and 2. • Wire connectors can be removed to simplify wiring.
  • Page 9: Wiring A Gate Operator (Normally Open)

    INTRODUCTION INSTALLATION TESTING PROGRAMMING WIRING A GATE OPERATOR (NORMALLY OPEN) & A DOOR STRIKE LOCK (NORMALLY OPEN) The door strike can be connected to Relay 1 or Relay 2. See the Programming section for information about configuring Relays 1 and 2. •...
  • Page 10: Wiring A Gate Operator (Normally Open)

    INTRODUCTION INSTALLATION TESTING PROGRAMMING WIRING A GATE OPERATOR (NORMALLY OPEN) & A MAGLOCK (NORMALLY CLOSED) The maglock can be connected to Relay 1 or Relay 2. See the Programming section for information about configuring Relays 1 and 2. Maglock DC Power NOTE: Do not use the unit’s power supply for the maglock.
  • Page 11: Wiring A Door Strike Lock (Normally Open)

    INTRODUCTION INSTALLATION TESTING PROGRAMMING WIRING A DOOR STRIKE LOCK (NORMALLY OPEN) The door strike can be connected to Relay 1 or Relay 2. See the Programming section for information about configuring Relays 1 and 2. • Wire connectors can be removed to simplify wiring.
  • Page 12: Earth Ground Rod

    POWER WIRE TABLE Power (included) DISTANCE AC POWER WIRE SIZE Under 30 feet 18 AWG 30 - 75 feet 18 AWG The EL1SS MUST be Dedicated Outlet 75 - 150 feet 18 AWG grounded. 150 - 250 feet 16 AWG...
  • Page 13: Plug The Transformer Into The Outlet

    Check the Power LED is illuminated. NOTE: Once power is applied, the EL1SS will begin to click to indicate that it is powered, and is waiting to be programmed for the unit’s Master Code. The Master Code is used to unlock the programming functions of the EL1SS.
  • Page 14: Testing

    3. To test Relay 1 have someone answer the telephone and enter Call Button “*9” (Star + 9). The EL1SS will disconnect the call as soon as the relay is activated. To test Relay 2 have someone answer the telephone and enter “*5” (Star + 5). The EL1SS will...
  • Page 15: General Instruction

    INTRODUCTION INSTALLATION TESTING PROGRAMMING GENERAL INSTRUCTION NOTE: Use the STAR Key “*” to cancel any input. PROGRAMMING INSTRUCTION SYNTAX KEYSTROKES General Programming Master Code + Command 1234 + 1 (12,123) Code Programming Master Code + Command + Code 1234 +1(12) + 1234 Relay Programming Master Code + Command + Setting 1234 + 123 + 1234...
  • Page 16: Code Setup

    3. Enter User Code to be deleted: CODE OPERATION ENTER A TEMPORARY (1 SHOT) USER CODE NUMBER MASTER CODE OPERATIONS The EL1SS holds 1 temporary User Code. TRIGGER RELAY 1 (ONLY) 1. Enter the Master Code: Enter the Master Code: NOTE: Requires Relay 2 be in Independent Mode.
  • Page 17: Telephone Programming

    1. Enter the Master Code: Up to a 14 Digit Telco Number 2. Enter the Program Code: To disengage party mode: Enter a valid code into the EL1SS keypad or enter “*9” into the local telephone. VERIFY CALL FORWARDING NUMBER (VIA CALLER ID)
  • Page 18: Telephone Commands

    Press “Flash” once to answer guest, Once again to return to outside call on telco line, if is not DISABLE “DO NOT DISTURB” MODE pressed. If (relay 1) or (relay 2) is Enter the command tone: pressed, the EL1SS will automatically return to the telco line.
  • Page 19: Quick Reference

    INTRODUCTION INSTALLATION TESTING PROGRAMMING KEYPAD PROGRAMMING PROGRAMMING DESCRIPTION OF TASK FACTORY PROGRAMMING PROCEDURE NUMBER SETTING Delete User Code Master Code (4 digits) + 7 + User Code that is to be deleted (4 digits) Enter User Code Master Code (4 digits) + 9 + New User Code (4 digits) + Relay/Channel Associated with the User Code (1 or 2) Enable Intercom (No-Telco) Master Code (4 digits) + 03...
  • Page 20 User Code + 1 Triggers Relay 1 User Code + 2 Triggers Relay 2 AUDIO FEEDBACK FROM THE EL1SS: 1 Low Tone Beep = Failure 2 Two High Tone Beeps = Valid sequence 3 Low Tone Beep = Error or invalid sequence NOTE: Use the STAR Key “*”...
  • Page 21 INTRODUCTION INSTALLATION TESTING PROGRAMMING DIRECT COMMANDS FROM THE LOCAL TELEPHONE PROGRAMMING DESCRIPTION OF TASK FACTORY PROGRAMMING PROCEDURE NUMBER SETTING Triggers Relay 2 Triggers Relay 1 **04 Enable Party (Latched) Mode **04 Relay 1 **05 Disable Party (Latched) Mode Relay 1 **11 Enable “Do Not Disturb”...
  • Page 22: Repair Parts

    DESCRIPTION KSN1600341B Bypass board K002B0821-1 Transformer 16.5 VDC 2.5 A K002B0799-3 Keys K002B1597-1 Keypad K001D7121-1 Main Board K002B1598 Speaker K002B0799-4 Lock and keys K101C0232-1 Call Button EL1SS MASTER CODE Write down the Master Code and store in a secure location.
  • Page 23: Warranty

    WARRANTY LiftMaster (“Seller”) warrants to the first purchaser of this product, for the structure in which this product is originally installed, that it is free from defect in materials and/or workmanship for a period of one year from the date of purchase. The proper operation of this product is dependent on your compliance with the instructions regarding installation, operation, maintenance and testing.