Plc Settings For A/B Trigger From Differential Inputs - Photon Focus D/L-2048 User Manual

Cmos camera with gige interface
Table of Contents

Advertisement

7.10.3 PLC Settings for A/B Trigger from differential inputs

This settings connects the ISO_INC differential inputs to the A/B camera inputs. ISO_INC0 is
mapped to the A signal and ISO_INC1 to the B signal, see Table 7.2 (the visibility in the
PF_GEVPlayer must be set to Guru for this purpose).
The AB Trigger feature is not available on all camera revisions, see Appendix B
for a list of available features.
Feature
TriggerMode
TriggerSource
PLC_I2
PLC_I3
PLC_Q6_Variable0
PLC_Q6_Operator0
PLC_Q6_Variable1
PLC_Q6_Operator1
PLC_Q6_Variable2
PLC_Q6_Operator2
PLC_Q6_Variable3
PLC_Q7_Variable0
PLC_Q7_Operator0
PLC_Q7_Variable1
PLC_Q7_Operator1
PLC_Q7_Variable2
PLC_Q7_Operator2
PLC_Q7_Variable3
Table 7.2:
PLC Settings for A/B Trigger from differential inputs (<PLC> = in category
IPEngine/ProgrammableLogicController)
.
7.10 PLC
Value
Category
On
AcquisitionControl
ABTrigger
AcquisitionControl
Line2
<PLC>/SignalRoutingBlock
Line3
<PLC>/SignalRoutingBlock
PLC_I2
<PLC>/LookupTable/Q6
Or
<PLC>/LookupTable/Q6
Zero
<PLC>/LookupTable/Q6
Or
<PLC>/LookupTable/Q6
Zero
<PLC>/LookupTable/Q6
Or
<PLC>/LookupTable/Q6
Zero
<PLC>/LookupTable/Q6
PLC_I3
<PLC>/LookupTable/Q7
Or
<PLC>/LookupTable/Q7
Zero
<PLC>/LookupTable/Q7
Or
<PLC>/LookupTable/Q7
Zero
<PLC>/LookupTable/Q7
Or
<PLC>/LookupTable/Q7
Zero
<PLC>/LookupTable/Q7
111

Advertisement

Table of Contents
loading

Table of Contents