Configuring Enhanced Object Tracking Features
Configuring a Tracked List with a Percentage Threshold
To track by percentage threshold, configure a tracked list of objects, specify that a percentage will be
used as the threshold, and specify a percentage for all objects in the list. The state of the list is determined
by comparing the assigned percentage of each object to the list.
You cannot use the Boolean "NOT" operator in a percentage threshold list.
Beginning in privileged EXEC mode, follow these steps to configure a tracked list of objects by using a
percentage threshold:
Command
Step 1
configure terminal
Step 2
track track-number list threshold
percentage
Step 3
object object-number
Step 4
threshold percentage {up number |
[down number]}
Step 5
delay {up seconds [down seconds] |
[up seconds] down seconds}
Step 6
end
Step 7
show track object-number
Step 8
copy running-config startup-config (Optional) Save your entries in the configuration file.
Use the no track track-number global configuration command to delete the tracked list.
This example configures tracked list 4 with three objects and a specified percentages to measure the state
of the list:
Switch(config)# track 4 list threshold percentage
Switch(config-track)# object 1
Switch(config-track)# object 2
Switch(config-track)# object 3
Switch(config-track)# threshold percentage up 51 down 10
Switch(config-track)# exit
Catalyst 3750-X and 3560-X Switch Software Configuration Guide
1-6
Purpose
Enter global configuration mode.
Configure a tracked list object and enter tracking configuration mode. The
track-number can be from 1 to 500.
threshold—Specify the state of the tracked list based on a threshold.
percentage—Specify that the threshold is based on percentage.
Specify the object to be tracked. The range is from 1 to 500.
An object must exist before you can add it to a tracked list.
Note
Specify the threshold percentage.
up number—The valid range is from 1 to 100.
down number]—(Optional) The range depends on the number selected
for the up number. If you configure the up number as 25, the range
shown for the down number is 0 to 24.
(Optional) Specify a period of time in seconds to delay communicating state
changes of a tracked object. The range is from 1 to 180 seconds.
Return to privileged EXEC mode.
Verify that the specified objects are being tracked.