S e t t i n g t h e S c a n n e r M o d e
To set the scanner mode without using the Scanner Configuration menu:
1.
Tap the printer icon in the System Tray.
Set the Scanner Mode: Momentary, Continuous, or Compatible.
2.
Momentary
Continuous
Compatible
Note:
A bad scan turns off the scanner and activates the tone (.wav
file) set in Scanner Configuration.
S e t t i n g t h e T r i g g e r M o d e
To set the trigger mode without using Scanner Configuration:
1.
Tap the printer icon in the System Tray.
Set the Trigger Mode: Scan, Drop, or Forward. The default is
2.
Forward.
Scan
Drop
Forward
The scanner is on as long as the trigger is pressed
and goes off when the trigger is released.
The scanner is always on. A good scan causes the
scanner to reset and continue scanning.
The scanner operates in Monarch® 6037
compatible mode. The scanner is on as long as the
trigger is pressed and goes off after a successful
scan or a predetermined timeout period.
Pressing the trigger activates the scanner.
The printer ignores the trigger press and does NOT
activate the scanner.
The printer passes the trigger press to the application,
which simulates pressing F11.
Using Scanner Diagnostics 6-3