GE Multilin F35 Instruction Manual page 402

Multiple feeder protection system ur series
Table of Contents

Advertisement

B.4 MEMORY MAPPING
Table B–9: MODBUS MEMORY MAP (Sheet 45 of 48)
ADDR
REGISTER NAME
CAD9
Direct I/O Channel 2 CRC Alarm Message Count
CADA
Direct Input/Output Channel 2 CRC Alarm Threshold
CADB
Direct Input/Output Channel 2 CRC Alarm Events
CADC
Reserved (4 items)
CAE0
Direct I/O Ch 1 Unreturned Messages Alarm Function
B
CAE1
Direct I/O Ch 1 Unreturned Messages Alarm Msg Count
CAE2
Direct I/O Ch 1 Unreturned Messages Alarm Threshold
CAE3
Direct I/O Ch 1 Unreturned Messages Alarm Events
CAE4
Reserved (4 items)
CAE8
Direct IO Ch 2 Unreturned Messages Alarm Function
CAE9
Direct I/O Ch 2 Unreturned Messages Alarm Msg Count
CAEA
Direct I/O Ch 2 Unreturned Messages Alarm Threshold
CAEB
Direct I/O Channel 2 Unreturned Messages Alarm Events
CAEC
Reserved (4 items)
Remote Devices (Read/Write Setting) (16 modules)
CB00
Remote Device 1 GSSE/GOOSE Application ID
CB21
Remote Device 1 GOOSE Ethernet APPID
CB22
Remote Device 1 GOOSE Dataset
CB23
...Repeated for Device 2
CB46
...Repeated for Device 3
CB69
...Repeated for Device 4
CB8C
...Repeated for Device 5
CBAF
...Repeated for Device 6
CBD2
...Repeated for Device 7
CBF5
...Repeated for Device 8
CC18
...Repeated for Device 9
CC3B
...Repeated for Device 10
CC5E
...Repeated for Device 11
CC81
...Repeated for Device 12
CCA4
...Repeated for Device 13
CCC7
...Repeated for Device 14
CCEA
...Repeated for Device 15
CD0D
...Repeated for Device 16
Remote Inputs (Read/Write Setting) (64 modules)
CFA0
Remote Input 1 Device
CFA1
Remote Input 1 Item
CFA2
Remote Input 1 Default State
CFA3
Remote Input 1 Events
CFA4
Remote Input 1 Name
CFAA
...Repeated for Remote Input 2
CFB4
...Repeated for Remote Input 3
CFBE
...Repeated for Remote Input 4
CFC8
...Repeated for Remote Input 5
CFD2
...Repeated for Remote Input 6
CFDC
...Repeated for Remote Input 7
CFE6
...Repeated for Remote Input 8
CFF0
...Repeated for Remote Input 9
CFFA
...Repeated for Remote Input 10
D004
...Repeated for Remote Input 11
D00E
...Repeated for Remote Input 12
D018
...Repeated for Remote Input 13
D022
...Repeated for Remote Input 14
D02C
...Repeated for Remote Input 15
D036
...Repeated for Remote Input 16
B-52
RANGE
100 to 10000
1 to 1000
0 to 1
1 to 1000
0 to 1
100 to 10000
1 to 1000
0 to 1
1 to 1000
0 to 1
100 to 10000
1 to 1000
0 to 1
---
---
0 to 16383
0 to 8
1 to 16
0 to 64
0 to 3
0 to 1
1 to 64
F35 Multiple Feeder Protection System
APPENDIX B
UNITS
STEP
FORMAT
---
1
F001
---
1
F001
---
1
F102
---
1
F001
---
1
F102
---
1
F001
---
1
F001
---
1
F102
---
1
F001
---
1
F102
---
1
F001
---
1
F001
---
1
F102
---
1
F001
---
---
F209
"Remote Device 1"
---
1
F001
---
1
F184
---
1
F001
---
1
F156
---
1
F086
---
1
F102
---
1
F205
DEFAULT
600
10
0 (Disabled)
10
0 (Disabled)
600
10
0 (Disabled)
10
0 (Disabled)
600
10
0 (Disabled)
10
0
0 (Fixed)
1
0 (None)
0 (Off)
0 (Disabled)
"Rem Ip 1"
GE Multilin

Advertisement

Table of Contents
loading

Table of Contents