B.4 MEMORY MAPPING
Table B–9: MODBUS MEMORY MAP (Sheet 23 of 48)
ADDR
REGISTER NAME
75A9
...Repeated for disconnect switch 6
75BE
...Repeated for disconnect switch 7
75D3
...Repeated for disconnect switch 8
75E8
...Repeated for disconnect switch 9
75FD
...Repeated for disconnect switch 10
B
7612
...Repeated for disconnect switch 11
7627
...Repeated for disconnect switch 12
763C
...Repeated for disconnect switch 13
7651
...Repeated for disconnect switch 14
7666
...Repeated for disconnect switch 15
767B
...Repeated for disconnect switch 16
7690
...Repeated for disconnect switch 17
76A5
...Repeated for disconnect switch 18
76BA
...Repeated for disconnect switch 19
76CF
...Repeated for disconnect switch 20
76E4
...Repeated for disconnect switch 21
76F9
...Repeated for disconnect switch 22
770E
...Repeated for disconnect switch 23
7723
...Repeated for disconnect switch 24
User Programmable Pushbuttons (Read/Write Setting) (16 modules)
7B60
User Programmable Pushbutton 1 Function
7B61
User Programmable Pushbutton 1 Top Line
7B6B
User Programmable Pushbutton 1 On Text
7B75
User Programmable Pushbutton 1 Off Text
7B7F
User Programmable Pushbutton 1 Drop-Out Time
7B80
User Programmable Pushbutton 1 Target
7B81
User Programmable Pushbutton 1 Events
7B82
User Programmable Pushbutton 1 LED Operand
7B83
User Programmable Pushbutton 1 Autoreset Delay
7B84
User Programmable Pushbutton 1 Autoreset Function
7B85
User Programmable Pushbutton 1 Local Lock
7B86
User Programmable Pushbutton 1 Message Priority
7B87
User Programmable Pushbutton 1 Remote Lock
7B88
User Programmable Pushbutton 1 Reset
7B89
User Programmable Pushbutton 1 Set
7B8A
User Programmable Pushbutton 1 Hold
7B8B
...Repeated for User Programmable Pushbutton 2
7BB6
...Repeated for User Programmable Pushbutton 3
7BE1
...Repeated for User Programmable Pushbutton 4
7C0C
...Repeated for User Programmable Pushbutton 5
7C37
...Repeated for User Programmable Pushbutton 6
7C62
...Repeated for User Programmable Pushbutton 7
7C8D
...Repeated for User Programmable Pushbutton 8
7CB8
...Repeated for User Programmable Pushbutton 9
7CE3
...Repeated for User Programmable Pushbutton 10
7D0E
...Repeated for User Programmable Pushbutton 11
7D39
...Repeated for User Programmable Pushbutton 12
7D64
...Repeated for User Programmable Pushbutton 13
7D8F
...Repeated for User Programmable Pushbutton 14
7DBA
...Repeated for User Programmable Pushbutton 15
7DE5
...Repeated for User Programmable Pushbutton 16
Underfrequency (Read/Write Setting) (6 modules)
7E10
Underfrequency Function
7E11
Underfrequency 1 Block
B-30
RANGE
0 to 2
---
---
---
0 to 60
0 to 2
0 to 1
0 to 65535
0 to 600
0 to 1
0 to 65535
0 to 2
0 to 65535
0 to 65535
0 to 65535
0 to 10
0 to 1
0 to 65535
F35 Multiple Feeder Protection System
APPENDIX B
UNITS
STEP
FORMAT
---
1
F109
---
---
F202
---
---
F202
---
---
F202
s
0.05
F001
---
1
F109
---
1
F102
---
1
F300
s
0.05
F001
---
1
F102
---
1
F300
---
1
F220
---
1
F300
---
1
F300
---
1
F300
s
0.1
F001
---
1
F102
---
1
F300
DEFAULT
2 (Disabled)
(none)
(none)
(none)
0
0 (Self-reset)
0 (Disabled)
0
0
0 (Disabled)
0
0 (Disabled)
0
0
0
1
0 (Disabled)
0
GE Multilin