Table B–9: MODBUS MEMORY MAP (Sheet 28 of 48)
ADDR
REGISTER NAME
9205
Fault Report 1 Z0 Angle
9206
Fault Report 1 Line Length Units
9207
Fault Report 1 Line Length
9208
Fault Report 1 VT Substitution
9208
Fault Report 1 System Z0 Magnitude
9208
Fault Report 1 System Z0 Angle
920B
...Repeated for Fault Report 2
9216
...Repeated for Fault Report 3
9221
...Repeated for Fault Report 4
922C
...Repeated for Fault Report 5
dcmA Outputs (Read/Write Setting) (24 modules)
9300
dcmA Output 1 Source
9301
dcmA Output 1 Range
9302
dcmA Output 1 Minimum
9304
dcmA Output 1 Maximum
9306
...Repeated for dcmA Output 2
930C
...Repeated for dcmA Output 3
9312
...Repeated for dcmA Output 4
9318
...Repeated for dcmA Output 5
931E
...Repeated for dcmA Output 6
9324
...Repeated for dcmA Output 7
932A
...Repeated for dcmA Output 8
9330
...Repeated for dcmA Output 9
9336
...Repeated for dcmA Output 10
933C
...Repeated for dcmA Output 11
9342
...Repeated for dcmA Output 12
9348
...Repeated for dcmA Output 13
934E
...Repeated for dcmA Output 14
9354
...Repeated for dcmA Output 15
935A
...Repeated for dcmA Output 16
9360
...Repeated for dcmA Output 17
9366
...Repeated for dcmA Output 18
936C
...Repeated for dcmA Output 19
9372
...Repeated for dcmA Output 20
9378
...Repeated for dcmA Output 21
937E
...Repeated for dcmA Output 22
9384
...Repeated for dcmA Output 23
938A
...Repeated for dcmA Output 24
Direct Input/Output Names (Read/Write Setting) (96 modules)
9400
Direct Input 1 Name
9406
Direct Output 1 Name
940C
...Repeated for Direct Input/Output 2
9418
...Repeated for Direct Input/Output 3
9424
...Repeated for Direct Input/Output 4
9430
...Repeated for Direct Input/Output 5
943C
...Repeated for Direct Input/Output 6
9448
...Repeated for Direct Input/Output 7
9454
...Repeated for Direct Input/Output 8
9460
...Repeated for Direct Input/Output 9
946C
...Repeated for Direct Input/Output 10
9478
...Repeated for Direct Input/Output 11
9484
...Repeated for Direct Input/Output 12
9490
...Repeated for Direct Input/Output 13
949C
...Repeated for Direct Input/Output 14
GE Multilin
RANGE
25 to 90
0 to 1
0 to 2000
0 to 2
0.01 to 650.00
25 to 90
0 to 65535
0 to 2
–90 to 90
–90 to 90
0 to 96
1 to 96
F35 Multiple Feeder Protection System
B.4 MEMORY MAPPING
UNITS
STEP
FORMAT
degrees
1
F001
---
1
F147
0.1
F001
---
1
F270
ohms
0.01
F001
degrees
1
F001
---
1
F600
---
1
F522
pu
0.001
F004
pu
0.001
F004
---
1
F205
---
1
F205
DEFAULT
75
0 (km)
1000
0 (None)
900
B
75
0
0 (–1 to 1 mA)
0
1000
"Dir Ip 1"
"Dir Out 1"
B-35