GE Multilin F35 Instruction Manual page 360

Multiple feeder protection system ur series
Table of Contents

Advertisement

B.4 MEMORY MAPPING
Table B–9: MODBUS MEMORY MAP (Sheet 3 of 48)
ADDR
REGISTER NAME
User Displays Actuals (Read Only)
1080
Formatted user-definable displays (16 items)
Modbus User Map Actuals (Read Only)
1200
User Map Values (256 items)
Element Targets (Read Only)
B
14C0
Target Sequence
14C1
Number of Targets
Element Targets (Read/Write)
14C2
Target to Read
Element Targets (Read Only)
14C3
Target Message
Digital Input/Output States (Read Only)
1500
Contact Input States (6 items)
1508
Virtual Input States (8 items)
1510
Contact Output States (4 items)
1518
Contact Output Current States (4 items)
1520
Contact Output Voltage States (4 items)
1528
Virtual Output States (6 items)
1530
Contact Output Detectors (4 items)
Remote Input/Output States (Read Only)
1540
Remote Device States
1542
Remote Input States (4 items)
1550
Remote Devices Online
Platform Direct Input/Output States (Read Only)
15C0
Direct input states (6 items)
15C8
Direct outputs average message return time 1
15C9
Direct outputs average message return time 2
15CA
Direct inputs/outputs unreturned message count - Ch. 1
15CB
Direct inputs/outputs unreturned message count - Ch. 2
15D0
Direct device states
15D1
Reserved
15D2
Direct inputs/outputs CRC fail count 1
15D3
Direct inputs/outputs CRC fail count 2
Ethernet Fibre Channel Status (Read/Write)
1610
Ethernet primary fibre channel status
1611
Ethernet secondary fibre channel status
Data Logger Actuals (Read Only)
1618
Data logger channel count
1619
Time of oldest available samples
161B
Time of newest available samples
161D
Data logger duration
Source Current (Read Only) (6 modules)
1800
Source 1 Phase A Current RMS
1802
Source 1 Phase B Current RMS
1804
Source 1 Phase C Current RMS
1806
Source 1 Neutral Current RMS
1808
Source 1 Phase A Current Magnitude
180A
Source 1 Phase A Current Angle
180B
Source 1 Phase B Current Magnitude
180D
Source 1 Phase B Current Angle
180E
Source 1 Phase C Current Magnitude
1810
Source 1 Phase C Current Angle
1811
Source 1 Neutral Current Magnitude
1813
Source 1 Neutral Current Angle
B-10
RANGE
---
0 to 65535
0 to 65535
0 to 65535
0 to 65535
---
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 1
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 2
0 to 2
0 to 16
0 to 4294967295
0 to 4294967295
0 to 999.9
0 to 999999.999
0 to 999999.999
0 to 999999.999
0 to 999999.999
0 to 999999.999
-359.9 to 0
0 to 999999.999
-359.9 to 0
0 to 999999.999
-359.9 to 0
0 to 999999.999
-359.9 to 0
F35 Multiple Feeder Protection System
UNITS
STEP
FORMAT
---
---
F200
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
---
F200
---
1
F500
---
1
F500
---
1
F500
---
1
F500
---
1
F500
---
1
F500
---
1
F500
---
1
F500
---
1
F500
---
1
F126
---
1
F500
ms
1
F001
ms
1
F001
---
1
F001
---
1
F001
---
1
F500
---
1
F001
---
1
F001
---
1
F001
---
1
F134
---
1
F134
channel
1
F001
seconds
1
F050
seconds
1
F050
days
0.1
F001
A
0.001
F060
A
0.001
F060
A
0.001
F060
A
0.001
F060
A
0.001
F060
degrees
0.1
F002
A
0.001
F060
degrees
0.1
F002
A
0.001
F060
degrees
0.1
F002
A
0.001
F060
degrees
0.1
F002
APPENDIX B
DEFAULT
(none)
0
0
0
0
"."
0
0
0
0
0
0
0
0
0
0 (No)
0
0
0
0
0
0
0
0
0
0 (Fail)
0 (Fail)
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
GE Multilin

Advertisement

Table of Contents
loading

Table of Contents