GE Multilin F35 Instruction Manual page 364

Multiple feeder protection system ur series
Table of Contents

Advertisement

B.4 MEMORY MAPPING
Table B–9: MODBUS MEMORY MAP (Sheet 7 of 48)
ADDR
REGISTER NAME
2342
Fault 1 Prefault Phase A Current Angle
2343
Fault 1 Prefault Phase B Current Magnitude
2345
Fault 1 Prefault Phase B Current Angle
2346
Fault 1 Prefault Phase C Current Magnitude
2348
Fault 1 Prefault Phase C Current Angle
B
2349
Fault 1 Prefault Phase A Voltage Magnitude
234B
Fault 1 Prefault Phase A Voltage Angle
234C
Fault 1 Prefault Phase B Voltage Magnitude
234E
Fault 1 Prefault Phase B Voltage Angle
234F
Fault 1 Prefault Phase C Voltage Magnitude
2351
Fault 1 Prefault Phase C Voltage Angle
2352
Fault 1 Phase A Current Magnitude
2354
Fault 1 Phase A Current Angle
2355
Fault 1 Phase B Current Magnitude
2357
Fault 1 Phase B Current Angle
2358
Fault 1 Phase C Current Magnitude
235A
Fault 1 Phase C Current Angle
235B
Fault 1 Phase A Voltage Magnitude
235D
Fault 1 Phase A Voltage Angle
235E
Fault 1 Phase B Voltage Magnitude
2360
Fault 1 Phase B Voltage Angle
2361
Fault 1 Phase C Voltage Magnitude
2363
Fault 1 Phase C Voltage Angle
2364
Fault 1 Type
2365
Fault 1 Location based on Line length units (km or miles)
2366
...Repeated for Fault 2
238C
...Repeated for Fault 3
23B2
...Repeated for Fault 4
23D8
...Repeated for Fault 5
Autoreclose Status (Read Only) (6 modules)
2410
Autoreclose 1 Count
2411
Autoreclose 2 Count
2412
Autoreclose 3 Count
2413
Autoreclose 4 Count
2414
Autoreclose 5 Count
2415
Autoreclose 6 Count
Expanded FlexStates (Read Only)
2B00
FlexStates, one per register (256 items)
Expanded Digital Input/Output states (Read Only)
2D00
Contact Input States, one per register (96 items)
2D80
Contact Output States, one per register (64 items)
2E00
Virtual Output States, one per register (96 items)
Expanded Remote Input/Output Status (Read Only)
2F00
Remote Device States, one per register (16 items)
2F80
Remote Input States, one per register (64 items)
Oscillography Values (Read Only)
3000
Oscillography Number of Triggers
3001
Oscillography Available Records
3002
Oscillography Last Cleared Date
3004
Oscillography Number Of Cycles Per Record
Oscillography Commands (Read/Write Command)
3005
Oscillography Force Trigger
3011
Oscillography Clear Data
B-14
RANGE
-359.9 to 0
0 to 999999.999
-359.9 to 0
0 to 999999.999
-359.9 to 0
0 to 999999.999
-359.9 to 0
0 to 999999.999
-359.9 to 0
0 to 999999.999
-359.9 to 0
0 to 999999.999
-359.9 to 0
0 to 999999.999
-359.9 to 0
0 to 999999.999
-359.9 to 0
0 to 999999.999
-359.9 to 0
0 to 999999.999
-359.9 to 0
0 to 999999.999
-359.9 to 0
0 to 11
-3276.7 to 3276.7
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 65535
0 to 65535
0 to 400000000
0 to 65535
0 to 1
0 to 1
F35 Multiple Feeder Protection System
UNITS
STEP
FORMAT
degrees
0.1
F002
A
0.001
F060
degrees
0.1
F002
A
0.001
F060
degrees
0.1
F002
V
0.001
F060
degrees
0.1
F002
V
0.001
F060
degrees
0.1
F002
V
0.001
F060
degrees
0.1
F002
A
0.001
F060
degrees
0.1
F002
A
0.001
F060
degrees
0.1
F002
A
0.001
F060
degrees
0.1
F002
V
0.001
F060
degrees
0.1
F002
V
0.001
F060
degrees
0.1
F002
V
0.001
F060
degrees
0.1
F002
---
1
F148
---
0.1
F002
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F108
---
1
F108
---
1
F108
---
1
F108
---
1
F155
---
1
F108
---
1
F001
---
1
F001
---
1
F050
---
1
F001
---
1
F126
---
1
F126
APPENDIX B
DEFAULT
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0 (NA)
0
0
0
0
0
0
0
0 (Off)
0 (Off)
0 (Off)
0 (Off)
0 (Offline)
0 (Off)
0
0
0
0
0 (No)
0 (No)