IBM NetVista N2200w Reference Manual page 83

For windows-based terminal standard 1.5
Table of Contents

Advertisement

|
Reflashing the boot block from the recovery
|
CompactFlash card
Refer to the appropriate diagram (Diagram 1 or Diagram
2) that matches your NetVista system.
Read "Safety notices" on page v before you continue with
these instructions.
Perform these instructions using the thin client that
requires the new boot block:
1. Perform Steps 1 to 4 in "Removing the logic unit" on
page 65.
2. Remove the installed CompactFlash card by carefully
pulling the card out of the flash card slot. See
"Appendix D. CompactFlash card" on page 67 for
more information.
3. Carefully insert the recovery CompactFlash card into
the flash card slot.
4. Move the jumpers on headers A and B into
configuration 3 .
5. Reconnect the power cable to the logic unit.
6. Power on the thin client, and wait for the system
LED to flash green.
If the system LED flashes amber, the image was not
created. Replace the logic unit (see "Appendix A.
Replacing hardware parts" on page 59).
7. Power off the thin client.
8. Remove the recovery CompactFlash card.
9. Move the jumpers back into the default configuration
1 .
10. Install the original CompactFlash card into the flash
card slot.
11. Perform "Reassembling the thin client" on page 66.
Diagram 1
Appendix E. Recovering the boot block image
71