5 Troubleshooting
Fault
Fault
WTT* fault message
code
code
(HEX)
(DEZ)
38
56
Initial starting attempt failed
39
57
Initial starting attempt failed
– not restarting
3F
63
Wrong version dataset
loaded
4C
76
Overvoltage component
protection
508
Visit www.butlertechnik.com for more technical information and downloads.
Fig. 502 Overview of general faults entered in fault memory
www.butlertechnik.com
Fault details with double-
click in WTT*
No additional information
available
No additional information
available
No additional information
available
Switching off at extremely
high overvoltage for compo-
nent protection
Thermo Top Evo
Recommended workshop
action
In case of frequent occurrence
(> 10):
1) Troubleshooting in air
intake or in exhaust system
(see Section 5.7, Fig. 504,
Point 12)
2) Conduct troubleshooting
in fuel system (see
Section 5.7, Fig. 504,
Point 10)
3) Conduct check of meter-
ing pump (see Section 5.7,
Fig. 504, Point 5)
4) Conduct electrical test of
glow plug (see Section 5.7,
Fig. 504, Point 6)
In case of frequent occurrence
(> 3):
1) Troubleshooting in air
intake or in exhaust system
(see Section 5.7, Fig. 504,
Point 12)
2) Conduct troubleshooting
in fuel system (see
Section 5.7, Fig. 504,
Point 10)
3) Conduct check of meter-
ing pump (see Section 5.7,
Fig. 504, Point 5)
4) Conduct electrical test of
glow plug (see Section 5.7,
Fig. 504, Point 6)
Delete fault, fault release/carry
out heater lock-out on heater
(see Section 5.1.1), restart
heater
Conduct check of vehicle elec-
trical-system supply voltage
(also see Section 5.7, Fig. 504,
Point 1)