Paradyne COMSPHERE 3830 User Manual page 74

Comsphere 3800 series
Hide thumbs Also See for COMSPHERE 3830:
Table of Contents

Advertisement

COMSPHERE 3800 Series Modems – Model 3830
S46
Bad Lines Auto Originate
Register determines if the modem performs an automatic dial backup if
the leased lines fail.
Register has the following values:
0 = Disable
1 = 30 seconds
2 = 20 seconds
3 = 60 seconds
4 = 90 seconds
5 = 120 seconds
21 = 600 seconds
Factory setting is Disable. Note that the S46 = 2 command has an effect
that is out of sequence with the other values.
S47
Auto Dial Standby
Register determines if the modem performs an automatic dial standby if
in Dial Backup mode.
Register has the following values:
0 = Disable
1 = 15 minutes
2 = 1 hour
3 = 4 hours
255 = Test(2min)
Factory setting is Disable.
4-38
Table 4-3
(9 of 20)
Model 3830 S-Registers
August 1998
3830-A2-GB91-30