Dimensional Outline Drawing - Mitsubishi Electric vl-100u5-e Installation Manual

Lossnay ventilator
Hide thumbs Also See for vl-100u5-e:
Table of Contents

Advertisement

- Electrical work must be done by
an electrical contractor (a licensed
electrician) in accordance with
the technical standards of the
equipment and local regulations
to ensure safety.
- Bad wiring and mistakes in
electrical work could result in
electric shocks or fire.
- Use circuit breakers connected
to the power supply to protect
against short circuits.*
- Short circuits could result in fire.
Caution
- Install the unit only on a wall. Do
not install it on a ceiling.
Prohibited
- Injury could result if the unit falls.
- Do not install the unit in
excessively hot areas (40°C or
more), near open flames, in areas
prone to oily smoke, or where
it could come in contact with
organic solvents.
- Fire could result.
- Always place a cover on the
terminal block after construction
You must
work is complete.*
follow the
- Dust, humidity and the like could
instructions
given.
cause short circuits or fire.
- Wear gloves when attaching the
unit.
- Failure to wear gloves could result
in injury.

Dimensional outline drawing

Lossnay
Operating
core (Heat
indicator
Outside air
exchanger)
Filter
Louver
252
Pull cord
(VL-100U
-E only)
5
Power cord (with plug)
(VL-100U
-E only)
5
(effective length approx. 3 m)
1
1
Air exhaust
Exhaust
hole
air filter
Indoor air
140
90
exhaust
620
hole
Shutter knob
Shutter knob
(when shutter is
(when shutter
closed)
is open)
* Factory default
- Attach the unit so that the air
supply/exhaust pipes slope
downward toward outdoors.
- Rainwater entering the unit could
result in electric shock, fire or indoor
items getting wet.
- Install the provided weather
covers.
- Rainwater entering the unit could
result in electric shock, fire or indoor
items getting wet.
- Be sure to shut off circuit
breakers or remove the power
plug from the wall outlet if the
Lossnay will not be used for a
long period after installation.
- Failure to do so could result in
electric shock from deteriorated
insulation, or fire from a short circuit.
- When attaching the main unit
on the wall, press the main unit
against the wall and secure it
firmly with the two screws.
- The joint gap could cause the wall
to become dirty.
: VL-100EU
*1
Note
- In mid-rise and high-rise buildings or in
coastal and other areas prone to strong
winds, wind could blow into the unit when it is
not operating. Install the Lossnay where it will
not be directly subject to wind.
- Do not use the Lossnay in areas prone to
damage from salt or hot springs.
With panel open
With panel
closed
Louver
(when vertical)
Louver
(when horizontal)
22
200
226
Eng-2
-E only.
5
Air supply/exhaust
pipe A
Air supply/exhaust
pipe B
Weather cover
17
Wall
Wall
thickness
thickness
54
50 to 300
300 to 550
106
Unit (mm)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vl-100eu5-e

Table of Contents