Mitsubishi Electric VL-100ZSKRT-E Operating Instructions Manual

Mitsubishi Electric VL-100ZSKRT-E Operating Instructions Manual

Lossnay energy recovery ventilator

Advertisement

Quick Links

MITSUBISHI ELECTRIC LOSSNAY ENERGY RECOVERY VENTILATOR
MODEL
VL-100ZSKRT-E
Operating Instructions
Please read these instructions thoroughly to ensure safe and proper use. After reading, store the manual in
a handy location for easy access.
Before proceeding with operation, please be sure to read "Safety precautions", as it will tell you how to
operate the Lossnay ventilator properly and safely.
Do not install the unit yourself. (The safety and performance of customer-installed units is not guaranteed.)
(Remote Controller Model)
For Customer
Contents
Safety precautions ............................. 2
Features ............................................. 4
When using the unit ........................... 4
Names of parts ................................... 5
Operation ........................................... 7
Maintenance ...................................... 8
Troubleshooting ................................. 10
After-sales servicing ........................... 11
Specifications ..................................... 12
2001876H31301
Page

Advertisement

Table of Contents
loading

Summary of Contents for Mitsubishi Electric VL-100ZSKRT-E

  • Page 1: Table Of Contents

    2001876H31301 MITSUBISHI ELECTRIC LOSSNAY ENERGY RECOVERY VENTILATOR MODEL VL-100ZSKRT-E (Remote Controller Model) Operating Instructions For Customer Contents Page Safety precautions ......2 Features ..........4 When using the unit ......4 Names of parts ........5 Before you start the Lossnay ..... 6 Operation ...........
  • Page 2: Safety Precautions

    Safety precautions The following symbols indicate the degree of danger Symbols used in the text and on the main unit have the caused by incorrect handling of the product. following meanings. Do not install in Warning Caution Prohibited bathroom Incorrect handling may Incorrect handling may result Do not touch Be sure to ground...
  • Page 3 If an abnormality or failure occurs, immediately stop use and turn off the power supply isolator. Continuing use may result in smoke, fire, electric shock, or injury. <Examples of abnormalities/failures> - Pressing the switch does not start the rotation of rotors. - There is unusual noise or vibration during rotation.
  • Page 4: Features

    Safety precautions Handling the remote controller battery Observe the following instructions to ensure safe use of the remote controller and correct use of the remote controller lithium battery. Caution Do not leave the battery and remote controller in a location that is accessible by small children. Accidental swallowing may cause chemical burns.
  • Page 5: Names Of Parts

    Names of parts ■Main unit controller Operation lamps: Green * The operation lamps are off immediately after power is supplied to the unit. The lamps turn on only when the button on the OFF/ON remote controller is set to ON during operation. Wire Panel frame * When the...
  • Page 6: Before You Start The Lossnay

    Before you start the Lossnay 1. Preparing to turn the power on 3. Installing the remote controller holder Turn the power supply isolator on at the distribution Secure the remote controller holder with the board. supplied mounting screws. - We do not recommend that you operate the unit with Power supply the remote controller placed in the remote controller isolator...
  • Page 7: Operation

    Operation Press the buttons to operate. Turning on or off the operation lamps Switching the air volume to “HIGH” on the main unit Press the button. HIGH Press the button. - The main unit switches to the HIGH OFF/ON - Each press of the button switches the operation.
  • Page 8: Maintenance

    Maintenance 4. Removing the filter from the frame To maintain the Lossnay function for a long period of time, clean the filter to remove the adhered dirt and (1) Push the tabs in three locations on the side of dust when the filter maintenance notification lamp the filter frame with a pick, etc.
  • Page 9 Cleaning the panel and panel frame Assembling and checking after maintenance When the panel and panel frame are getting dirty, wipe off the dirt with a cloth soaked in kitchen neutral detergent diluted with lukewarm water (40°C Caution or less) and then wipe them with a dry cloth to remove the detergent residue.
  • Page 10: Troubleshooting

    Troubleshooting Perform an inspection if any of the following symptoms occur. If the problem is not solved by an inspection or if the symptom is not in the table below, turn off the power supply isolator and ask the dealer or contractor for inspection and repair. Phenomenon Cause Inspect...
  • Page 11: After-Sales Servicing

    After-sales servicing Consult with your dealer about the after-sales If you hear strange sounds, if no air is blown out services provided for this Lossnay product. or if some other trouble occurs, switch off the power and contact your dealer. Consult with your dealer concerning the cost of inspection or repair work.
  • Page 12: Specifications

    Air exhaust Air supply Cooling Heating High 38.5 13.5 High VL-100ZSKRT-E 25.5 High 41.5 16.5 * The noise values may be greater than those above depending on the room structure. Manufactured by: MITSUBISHI ELECTRIC CORPORATION TOKYO BLDG. 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO, 100-8310 JAPAN...

Table of Contents