Download Print this page
Mitsubishi Electric VL-50S2-E Operating Instructions Manual

Mitsubishi Electric VL-50S2-E Operating Instructions Manual

Mitsubishi lossnay ventilator pull cord type wall switch type
Hide thumbs Also See for VL-50S2-E:

Advertisement

Mitsubishi Lossnay Ventilator
MODELS
VL-50S
-E
2
VL-50ES
2

Operating Instructions

Please read these instructions thoroughly to ensure safe and proper use. After reading, store the manual
in a handy location for easy access.
Before proceeding with operation, please be sure to read "Safety precautions", as it will tell you how to
operate the Lossnay ventilator properly and safely.
Do not install the unit yourself. (The safety and performance of customer-installed units is not
guaranteed.)
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or a similarly
- Contact your dealer.

1. Safety precautions

Hazards created by mishandling and their
severity are indicated by the following
markers.
Warning:
This applies to mishandling or misoperation
of the product which could lead to a fatal or
serious injury.
Caution:
This applies to mishandling or misoperation
of the product which will lead to an injury or
damage to your home, household effects, etc.
(pull cord Type)
-E
(wall switch Type)
Contents
1. Safety precautions ............................... 1
2. When using the unit ............................. 3
3. Features ............................................... 4
4. Names of parts ....................................
6. Operation ............................................. 6
7. Maintenance ........................................ 7
8. Troubleshooting ...................................
-E only)
2
Warning
- Do not cut, damage or physically
alter the power cord
Prohibited
to unreasonable bending, pulling,
twisting or bundling.
- You could damage the cord,
- Do not turn the Lossnay switch ON
leak.
-
cause explosions. Open a window to
ventilate the room.
Eng-1
For Customer
Page
...............
....................................... 11
........................... 11
or subject it
*1

Advertisement

loading

Summary of Contents for Mitsubishi Electric VL-50S2-E

  • Page 1: Table Of Contents

    Mitsubishi Lossnay Ventilator MODELS VL-50S (pull cord Type) VL-50ES (wall switch Type) Operating Instructions For Customer Contents Page 1. Safety precautions ....... 1 2. When using the unit ......3 3. Features ..........4 4. Names of parts ........... 6.
  • Page 2 - Do not use the unit in excessively purchase for inspection and repair. hot areas (40°C or more), near <Examples of malfunction and smoke, or where it could come in - Blades do not turn when power is contact with organic solvents. turned on.
  • Page 3: When Using The Unit

    - Never remove the power plug by a person responsible for pulling on the cord. Always grasp their safety. Children should be the plug itself. supervised to ensure that they do not play with the appliance. (This appliance can be used by children aged from 8 years and - If the outside air is cold, winds above and persons with reduced...
  • Page 4: Features

    - In the following cases, stop the Lossnay and close its shutter. Lossnay away from the bed. - If the outside air is cold, winds are strong, snow If the unit is too close, you may hear operating or rain is falling heavily, there is heavy fog, or noise or feel cold air blowing while in bed.
  • Page 5: Names Of Parts

    4. Names of parts Panel Wire (fall prevention) Operation lamp Display (Remove the provided protective sheet.) Lossnay Core Pull cord (Heat exchanger) -E only) 5. Before you start the Lossnay 1. Preparing to turn the power on -E only) Power plug Eng-5...
  • Page 6: Operation

    6. Operation Note 3. Operation in Exhaust only mode - In the following cases, stop the Lossnay What is Exhaust only mode? and manually move the shutter knob to the When the outside air temperature becomes low leftmost position (the closed position) to close the shutter.
  • Page 7: Maintenance

    7. Maintenance wallpaper could be damaged.) cores at regular intervals in order to prevent a deterioration in the Lossnay functions. Guideline: Wire Panel at least once every six months Clean the Lossnay cores once two year. (Frequency should be increased depending on the extent of dirt.) Warning: - Always shut off circuit breakers or, for the VL-...
  • Page 8 Replacement: -E) when it has been washed four times. out. 2) Either lightly tap with your hand or remove dust with a vacuum cleaner. 3) If it is excessively dirty, wipe with a cloth (5) Remove the Lossnay Core. Push sideways to remove the tab Press the prong of the Lossnay Core's handle and pull the handle toward you to remove the...
  • Page 9 Reassembly and checking after maintenance opposite of the removal procedure. Caution - After maintenance, reattach parts securely. (1) Mount the Lossnay Core. Main unit catch 2) Insert the Lossnay Core guide along the rail Outside air Filter frame of the main unit. (4) Close the panel.
  • Page 10: Troubleshooting

    8. Troubleshooting Inspect the unit if any of the following problems occurs. If the problem is not listed below, or the problem -E, remove the power plug from the wall outlet, and then contact your dealer. Model Problem Cause Page -E only) Unit does not operate.
  • Page 11 - Abnormal noise or vibration due to the motor reaching the end of its service life The following are consumables: - Motor - Lossnay core Manufactured by: Importer in EU: MITSUBISHI ELECTRIC EUROPE B.V. HARMAN HOUSE, 1 GEORGE STREET, UXBRIDGE, MIDDLESEX, UB8 1QQ, U.K. Eng-11...