XPM 80™ Thermal Printer Family

6.3.3. Paper Pre-End

The location of the Paper Pre-End connector is shown in Figure 4, while Figure 6
shows the location of the individual pins within the connector. Figure 6A shows the
input circuit for these sensor connectors. The Side A PPE connector is the primary
PPE connector and is located under the print egress point. A second PPE connector
may also be located on Side B in some units, for convenience in making connections
in some installations. The characters in parenthesis show the input as it is labeled in
the XPM 80™ Diagnostic Tool.
PPE Connector Side A
Pin 7 – PPE Sensor Signal Path 1 (A1)
Pin 5 – PPE Sensor Power Path 1 (A1)
Pin 6 – PWE Sensor Signal Path 1 (B1)
Pin 8 – Common (Ground)
Pin 2 – PPE Sensor Signal Path 2 (A2)
Pin 4 – PPE Sensor Power Path 2 (A2)
Pin 3 – PWE Sensor Signal Path 2 (B2)
Pin 1 – Common (Ground)
Part No. D 690 019
Figure 6
PPE Connector Side B
Pin 7 – PPE Sensor Signal Path 2 (A2)
Pin 5 – PPE Sensor Power Path 2 (A2)
Pin 6 – PWE Sensor Signal Path 2 (B2)
Pin 8 – Common (Ground)
Pin 2 – PPE Sensor Signal Path 1 (A1)
Pin 4 – PPE Sensor Power Path 1 (A1)
Pin 3 – PWE Sensor Signal Path 1 (B1)
Pin 1 – Common (Ground)