Trouble Mode Process; Writing To The Trouble Memory; Power On Trouble Detection Sequence - Sharp AR-M550N Service Manual

Hide thumbs Also See for AR-M550N:
Table of Contents

Advertisement

: Feb. 9 2004
1

(2) Trouble mode process

The machine can be operated under some conditions.
Operations except for the trouble mode are enabled (READY). For the
modes which cannot be operated, only setting is enabled and a mes-
sage is given to show the operations are disabled. (NOT READY in this
case)
(Display)
When a trouble occurs, a dialog is shown. In the mode where the oper-
ation is enabled, the OK button is added to the message. In the mode
where the operation is disabled, the OK button is not shown and the
display is kept until the trouble is canceled.
B. Power ON trouble detection sequence.
• When the power is turned ON, if H3, H4, H5, U1, U2, PF, L4-31, F3-12/22, or U6 (LCC-related sub code 09 only) is saved, a trouble code is imme-
diately displayed. E7 (50, 55, 56, 57, 60, 65, 66, 67) trouble is not saved.
(Power ON sequence)
·
H3, H4, U1, U2, U6 PF trouble check
Trouble check is made in each block when initializing
and data are sent to the ICU.
H3, H4, H5, L4-31, F3-12/22: Saved in the PCU.
U1: Saved in the ICU.
U2: Saved in each block.
PF: Saved in the ICU.
U6-09: Saved in the PCU.
(Trouble cancel sequence)
·
When executing SIM 13, 14, 15, 16, 17
SIM 13: U1 trouble cancel
SIM 14: H3, H4, H5, L4-31 trouble cancel
SIM 15: LCC (U6), Tray 1, 2 (F3-12, 22)
F3-12/22 trouble cancel
SIM 16: U2 trouble cancel
SIM 17: PF trouble cancel
ICU event
manager
sim task
(To the corresponding block)
1
AR-M550/M620/M700 SELF DIAG MESSAGE AND TROUBLESHOOTING 9 - 3

(3) Writing to the trouble memory

In case of a same trouble in this machine, selection is made with the
simulation to write into the trouble memory or not. If this simulation is
set, any trouble is written into the trouble memory unconditionally.
(SIMULATION. 26-35)
0: A same trouble as the previous one is not written. (Default)
1: Any trouble is written into the trouble memory unconditionally.
Communication of trouble status
[Trouble data ID] [Trouble code]
Trouble cancel command
Trouble cancel status is
communicated.
Each block
When the power is turned on,
check is made in each block.
Trouble cancel
(The trouble memory is
initialized.)