Sharp AR M550N - B/W Laser - Copier Installation Manual

Digital laser copier/printer digital multifunctional system
Hide thumbs Also See for AR M550N - B/W Laser - Copier:

Advertisement

[ 1 ] AR-M550/M620 UNPACKING AND INSTALLATION . . . . . . . . . . 1 - 1
[ 2 ] AR-LC6 UNPACKING AND INSTALLATION . . . . . . . . . . . . . . . . 2 - 1
[ 3 ] AR-CF2 UNPACKING AND INSTALLATION . . . . . . . . . . . . . . . . 3 - 1
[ 4 ] AR-F15/F16 UNPACKING AND INSTALLATION . . . . . . . . . . . . . 4 - 1
[ 5 ] AR-PN4 UNPACKING AND INSTALLATION . . . . . . . . . . . . . . . . 5 - 1
[ 6 ] AR-P19 INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 - 1
1
[ 7 ] AR-FR11 INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 - 1
1
[ 8 ] AR-PK5 INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 - 1
1
[ 9 ] AR-NS3 INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 - 1
1
[10] AR-FX8/AR-MM9 INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . 10 - 1
[11] MECHANICAL COUNTER INSTALLATION . . . . . . . . . . . . . . . . . 11-1
2
[12] DRY HEATER INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . 12-1
2
Parts marked with "
" are important for maintaining the safety of the machine. Be sure to replace these parts
with the replacement parts specified to maintain the safety and performance of the machine.
INSTALLATION MANUAL
DIGITAL LASER COPIER/PRINTER
DIGITAL MULTIFUNCTIONAL SYSTEM
AR-M550N/M550U
AR-M620N/M620U
AR-M700N/M700U
MODEL
CONTENTS
SHARP CORPORATION
CODE : 00ZAR700//I1E
This document has been published to be used
for after sales service only.
The contents are subject to change without notice.

Advertisement

Table of Contents
loading

Summary of Contents for Sharp AR M550N - B/W Laser - Copier

  • Page 1: Table Of Contents

    ” are important for maintaining the safety of the machine. Be sure to replace these parts with the replacement parts specified to maintain the safety and performance of the machine. This document has been published to be used SHARP CORPORATION for after sales service only. The contents are subject to change without notice.
  • Page 2: Unpacking And Installation

    [1] AR-M550/M620/M700 (3) Power frequency, waveform The frequency must be within the range of the specified frequency UNPACKING AND INSTALLATION ±2%. If power waveform is deformed, a trouble may occur. (4) Safety 1. Installing (use) conditions Be sure to properly ground the machine. Before installing the machine, check that the following installing (use) (5) Power plug conditions are satisfied.
  • Page 3: Transit And Delivery

    (2) Dust 2. Transit and delivery If dust enters the machine, it may cause dirty copy and a paper jam, Content Method resulting in a shortened lifetime. Implements, facility, Use a forklift. (If no forklift is available, and manpower manpower of four or more persons is required.) Delivery Transit must be made in packed...
  • Page 4 4) Remove the adjuster cover and the screw (in the bag). 8) Remove the slope. Slope: Parts Part name Part code Skid slope DKiT-0367FCZZ 5) Cut the four corners of the bottom case. 9) Attach the slope to the concave section of the skid. 6) Lift the machine slightly, and remove the bottom pad L.
  • Page 5 : Feb. 9 2004 B. Adjuster cover installation Packed items 1) Move the main unit to the installing position, and turn the adjuster to fix the main unit. 2) Remove the bottom tray from the main unit. Driver (CD-ROM) Operation manual Delivery and installation report Paper exit tray C.
  • Page 6 D. Lock release E. Press the fusing section (upper and lower heat rollers) and remove the process separation pawl Lock position fixing block. No. 2/3 mirror base lock screw 1) Pull the knob on the left door to pull out the left door. Tray rotation plate fixing material (1) No.
  • Page 7 F. Set developer 6) While supplying developer from the developer supply port of the developing unit, turn the MG gear clockwise with a plus screwdriver (1) Supply developer to supply all developer to the developing unit. 1) Open the front cabinet. 2) Loosen the blue screw of the process cover, and tilt down the pro- cess cover toward you.
  • Page 8 : Feb. 9 2004 (3) Set the toner density reference control level 4) Slowly insert the tray 1 and the tray 2. Insert the power plug into the power outlet, and turn on the power (2) Supply paper to the tray 3 and the tray 4 switch of the main unit.
  • Page 9 2) Set the manual paper feed guide to the set paper size. When removing the B5 size regulation plate, slightly press the paper feed base plate downward and press the hook under the reg- ulation plate to remove. 3) Set the paper with print face up and insert until it makes contact with the manual paper feed guide.
  • Page 10 (5) Tray 3 or tray 4 paper size change 4) Supply tab paper with the print face up into the tray 3. 1) Pull out the tray 3 or the tray 4. 2) Hold and slide the fixing knob (slide system) of the partition plates A and B to fit with the size of paper to be supplied.
  • Page 11 5) Select the type of paper that was loaded in the tray. 9) Set the attributes of the paper tray only if you have selected a user type. (Touch the checkboxes to the left of the items to select them.) Example: The paper type of tray 3 is selected.
  • Page 12 : Feb. 9 2004 4) Touch the [OK] key. (You will return to the size setting screen of H. The other parts setting step 2.) (1) Document exit tray installation Install the document exit tray to the scanner unit as shown in the figure below.
  • Page 13: Image Quality Check

    5. Image quality check Check the following contents. For adjustment and check procedures, refer to the chapter of adjustments. A. Focus (Resolution) B. Copy image off-center C. Image loss, void area 6. Specifications setting Use SIM 26 to set the customer's desired specifications. Sim No.
  • Page 14: Ar-Lc6 Unpacking And Installation

    [2] AR-LC6 UNPACKING AND A. Turn off the power of the main unit. 1) Turn OFF the power switch on the right side of the main unit. INSTALLATION 2) Open the front cabinet, and turn OFF the main power switch. 1.
  • Page 15 3) Remove the fixing screws (2 pcs.) of the machine entry port, and D. Remove the paper feed base screw of the large remove the entry port cover. capacity tray. 4) Attach the entry port cover reversely to the machine and fix it with 1) Slowly pull out the paper feed base tray until it stops.
  • Page 16 E. Attach the large capacity tray to the main unit. Note 2): Turn the lock release screw of the front cover counterclock- wise to loosen and check that the screw is free. 1) Hold the grips of the front and the rear cabinets with both hands, and lift the left side.
  • Page 17 F. Adjust the caster 2) Connect the large capacity tray interface harness connector and the heating heater interface harness connector to the main unit 1) After installing the large capacity tray to the main unit, loosen the connector, and tighten the connector screw to fix the connector. screws (one in the front and one in the rear) of the adjustment caster mounting plate attached to the lower side of the large capacity tray.
  • Page 18 a. Side plate size change-over b. Auxiliary guide size change-over 1) Remove the four fixing screws (blue) which are fixing the upper 1) When changing the size of the side plate R, check to confirm the and the lower sections of the side plate F and the side plate R. mark positions of "...
  • Page 19 3) Push the paper feed tray slightly, and return the disabled stopper I. Turn the main power switch on the main unit to to the original position, and tighten the fixing screw. the ON position. 1) Insert the power plug of the main unit to the outlet. 2) Turn the main power switch to the ON position.
  • Page 20 K. Carry out the print off center adjustment [When shifted to the rear side] When the print line is shifted from the center of paper in the direction B: (1) Adjustments with simulations Decrease the value. Since the off-center adjustment has been made at shipping, there is normally no need to adjust.
  • Page 21 3) Then pull out the paper feed tray again until it stops. [When shifted to the rear side] When shifting the print line from the paper center in the arrow direction as shown below: 4) Loosen the red fixing screws (2 pcs. for each) of the front/back size guide adjustment plate, and slide the side guide adjustment plate in the direction B (F side) by the shift dimension.
  • Page 22: 3 ] Ar-Cf2 Unpacking And Installation

    [3] AR-CF2 UNPACKING AND (Removal of the fixing member) 1) Remove the tape and open the upper door. INSTALLATION <Before installation> Start installation after checking that the DATA indicator on the opera- tion panel is neither lit nor blinking. 1. Unpacking (Removal of the main unit) 2) Remove the tape and remove the miramatte.
  • Page 23 : Jan. 9 2004 4) Remove the tape and open the base cover. (1) Turn off the power of the main unit 1) Turn OFF the power switch on the right side of the main unit. 2) Open the front cabinet, and turn OFF the main power switch. 5) Remove the connector cable fixing tape.
  • Page 24 : Jan. 9 2004 (3) Removal of the rail, the connectting plate, and the 2) Attach the positioning pin with two fixing screws I to the left upper earth plate section of the main unit. Be careful to the attachment direction of the positioning pin.
  • Page 25 : Jan. 9 2004 7) Attach the connecting plate to the with fixing screws I (2 pcs.) main (6) Install the upper limit regulation wire to the inserter unit. 1) Open the front door of the inserter, and install the upper limit regula- tion wire with the two fixing screws E.
  • Page 26 : Jan. 9 2004 3) Hold the lower section of the front cabinet and the grip of the rear 5) Check that the finisher lock lever is engaged on the inserter groove cabinet as shown in the figure, tilt the inserter a little so that the indi- securely.
  • Page 27 : Jan. 9 2004 (9) Install the connection plate. (Use the packaged parts of (11) Install the inserter to the main unit the finisher.) 1) Bring the inserter closer to the main unit. 1) Install the connection plate to the inserter with the fixing screws G (2 pieces.).
  • Page 28 A. When the positioning pin does not enter smoothly: (12) Finisher and inserter height adjustment 1) Loosen the adjustment section fixing screws (2 pcs.) on the rear 1) Check the height of the inserter front cabinet and the finisher front side.
  • Page 29 3) Loosen the fixing screws (2 pcs.) of the adjustment section of the 3) Use the spanner and adjust the height adjustment bolt so that the base. height of the rear side cabinet top surface is of the same height. 4) Use the spanner removed in step 1) to adjust the height adjustment 4) Tighten the adjustment section fixing screws (2 pcs.).
  • Page 30 : Jan. 9 2004 • When the upper and the lower clearances differ: 5) Check that the upper and the lower clearances are even when viewed from the front and the back. 1) Open the front upper door of the finisher, and remove the spanner (fixed with a screw) from the inside of the door.
  • Page 31 (15) Turn ON the main power switch 1) Insert the power plug of the main unit to the outlet. 2) Open the front cabinet, and open the power cover. 3) Turn ON the main power switch, close the power cover, and close the front cabinet.
  • Page 32: 4 ] Ar-F15/F16 Unpacking And Installation

    [4] AR-F15/F16 UNPACKING AND 4) Hold the upper section of the machine with two persons, and pull it up and stand it straight. INSTALLATION 1. Unpacking When removing or moving, be sure to perform by two persons not to drop the unit. A.
  • Page 33 7) One person holds the machine so that it does not fall down. The 2) Remove the tape and remove the protection board and the sheet. other person tilts the machine a little to remove packing material. 3) Remove the tape and open the upper cover. 8) Bring the base of the unit into contact with the floor so that it does not fall down.
  • Page 34 6) Remove the tape and the fixing member. 11) Open the lower door, and remove the each tape. 7) Remove the tape and remove the jam release door transit fixing member. 8) Remove the tape and remove the jam release door handle section transit fixing member.
  • Page 35 : Jan. 9 2004 B. Note for packing 2. Installation (1) Finisher transit fixing member installation A. Installation procedure 1) Remove the rear cabinet of the finisher. (1) Turn off the power of the main unit. 2) Turn on the power of the main unit. 1) Turn OFF the power switch on the right side of the main unit.
  • Page 36 2) Attach the earth plate with the fixing screws H (2 pcs.) to the left (3) Plate and connection plate installation lower section of the main unit. 1) Install the plate to the finisher as shown in the figure, and fix it with In this case, attach so that the R mark on the earth plate faces up.
  • Page 37 1) Remove the fixing screw of base cover (2 positions) in the front and 6) Turn the bolt with the removed spanner so that the guide pin is in the back of the finisher, and remove the base cover. the specified range of the scale. 2) Remove the fixing screws (2 pcs.) of the rear cover on the rear of the finisher, and remove the rear cover.
  • Page 38 (5) Attach the staple position label. (6) Connect the finisher connector. Attach the staple position label as shown in the figure. A. Remove the connector cover fixing screw for connection of the fin- isher joint harness connector, and remove the connector cover. B.
  • Page 39: 5 ] Ar-Pn4 Unpacking And Installation

    [5] AR-PN4 UNPACKING AND INSTALLATION 1. Unpacking Packaged parts (accessories) (1) Removal of the main unit Punch position label 2 pcs. 2. Installation (1) Turn off the power of the main unit. 1) Turn OFF the power switch on the right side of the main unit. 2) Open the front cabinet, and turn OFF the main power switch.
  • Page 40 (2) Punch cover disassembly (3) Paper guide disassembly 1) Remove the punch cover fixing screws (6 pcs.), and lift the punch 1) Remove the paper guide fixing screw (1 pc.) and remove the paper cover slightly to remove it from the finisher. guide from the finisher.
  • Page 41 (6) Punch cover assembly 1) Attach the rear cabinet B to the original position, and fit it with the fixing screws (2 pcs.). 2) Open the front door of the punch cover, attach the punch cover to the original position, and fix it with the fixing screws (6 pcs.). In this case, use the fixing screws at their original positions.
  • Page 42 2) Open the front cabinet, and open the power cover. 3) Turn ON the main power switch, close the power cover, and close the front cabinet. 4) Turn ON the power switch on the right side of the main unit. AR-M550/M620/M700 INSTALLATION MANUAL (AR-PN4) 5 - 4...
  • Page 43: 6 ] Ar-P19 Installation

    : Jan. 9 2004 [6] AR-P19 INSTALLATION 2) Remove the four screws that secure the control PWB unit to the main unit. 3) Raise the two grips and hold them to pull out the control PWB unit <Before installation> until the stopper is engaged. To enable the printer expansion function, the product key must be 4) Remove the two flat cable connectors.
  • Page 44 : Jan. 9 2004 (4) Reattach the control PWB. (6) Enable the printer expansion function. 1) Reattach the control PWB unit to the main unit. 1) To enable the printer expansion function, use the keys on the oper- ation panel to enter the product key. 2) Reconnect the two flat cable connectors that have been removed in step (2).
  • Page 45: 7 ] Ar-Fr11 Installation

    : Jan. 9 2004 [7] AR-FR11 INSTALLATION 2) Remove the four screws that secure the control PWB unit. 3) Raise the two grips and hold them to pull out the control PWB unit until the stopper is engaged. <Before installation> 4) Remove the two flat cable connectors.
  • Page 46 : Jan. 9 2004 (4) Reattach the control PWB. (6) Make preparations for enabling the data security function. 1) Reattach the control PWB unit to the main unit. To enable the data security function, use the keys on the operation 2) Reconnect the two flat cable connectors that have been removed panel to enter the product key.
  • Page 47: 8 ] Ar-Pk5 Installation

    : Jan. 9 2004 [8] AR-PK5 INSTALLATION <Before installation> • To enable the PS expansion function, the product key must be acquired. • For models on which the printer and network functions cannot be used, a printer expansion ROM and a Print Server Card must be installed in advance.
  • Page 48: 9 ] Ar-Ns3 Installation

    : Jan. 9 2004 [9] AR-NS3 INSTALLATION <Before installation> • To enable the scanner function, the product key must be acquired. • For models on which the printer and network functions cannot be used, a printer expansion ROM and a Print Server Card must be installed in advance.
  • Page 49: Ar-Fx8/Ar-Mm9 Installation

    [10] AR-FX8/AR-MM9 INSTALLATION <2>Remove the four screws that secure the MFP control PWB unit to the main unit. <3>Raise the two grips and hold them to pull out the MFP control PWB <Before installation> unit until the stopper is engaged. •...
  • Page 50 6) Reattach the MFP control PWB unit. 8) Attach the FAX box unit. <1>Reattach the MFP control PWB to the main unit. Among the four screws shown in the illustration that secure the <2>Connect the two flat cable connectors that have been removed in rear cabinet, remove the lower two screws and loosen the upper step 2).
  • Page 51 11) Turn on the main power switch and the power switch of the main 13) Set the destination of the FAX. unit. <1>Switch the operation panel to the copy mode and use the key <1>Insert the power plug of the main unit to the outlet. operation [P], [*], [C], and [*] to enter the simulation mode.
  • Page 52 14) Clear the image memory. 15) Connect the line cable to the FAX box unit. If an extended memory (AR-MM9) has been mounted in step 3), Connect the line cable to the FAX box unit. be sure to carry out this step. If no extended memory has been mounted, this step is not Line cable necessary.
  • Page 53: Mechanical Counter Installation

    : Feb. 9 2004 [11] MECHANICAL COUNTER INSTALLATION NOTE: The mechanical counter (KCOUM0027FCZZ) is treated as a service part. When ordering, order as a service part. 1) Open the front cabinet of the main unit, and cur off the counter cover with a cutter and pliers.
  • Page 54: Dry Heater Installation

    : Feb. 9 2004 [12] DRY HEATER INSTALLATION 4) Connect the ACWH harness and pass it through the wire saddle. 1. Dry heater switch and dehumidifying heater relay PWB installation Part name Part code Q’ty Dehumidifying heater switch QSW-C1030QCZZ Supporter LSUPP0118FCZZ Dehumidifying heater relay PWB CPWBF1569FCE1...
  • Page 55 : Feb. 9 2004 3) Remove the white reference glass unit, and remove the table glass. 7) Install the clamp, connect the SCN WH harness, and pass it through the clamp and fix with the snap band. 4) Remove the dark box. 8) Install the clamp, and install the dark box to the scanner base plate.
  • Page 56 : Feb. 9 2004 3. Dry heater (Paper feed trays 1, 2) 4) Fix the harness with the snap band, and pass it through the edge saddle. installation Part name Part code Q’ty Heater mounting plate LPLTM6089FCZZ Heater harness sheet PSHEZ5135FCZZ Dry heater (120V) RHETP0118FCZZ...
  • Page 57 : Feb. 9 2004 2) Remove the connector cover. 6) Install the dry heater (paper feed trays 3, 4) unit. 7) Fix the harness with the snap band, and pass it through the edge saddle. 3) Disconnect the connector. 8) Connect the connector to the dehumidifying heater relay PWB. 4) Remove the lower stage of the paper trays 3/4 paper feed unit.
  • Page 58 LEAD-FREE SOLDER The PWB’s of this model employs lead-free solder. The “LF” marks indicated on the PWB’s and the Service Manual mean “Lead-Free” solder. The alphabet following the LF mark shows the kind of lead-free solder. Example: <Solder composition code of lead-free solder> Solder composition Solder composition code Solder composition...
  • Page 59 CAUTION FOR BATTERY REPLACEMENT (Danish) ADVARSEL ! Lithiumbatteri – Eksplosionsfare ved fejlagtig håndtering. Udskiftning må kun ske med batteri af samme fabrikat og type. Levér det brugte batteri tilbage til leverandoren. (English) Caution ! Danger of explosion if battery is incorrectly replaced. Replace only with the same or equivalent type recommended by the manufacturer.
  • Page 60 COPYRIGHT © 2004 BY SHARP CORPORATION All rights reserved. Printed in Japan. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, electronic; mechanical; photocopying; recording or otherwise without prior written permission of the publisher.

This manual is also suitable for:

Ar-m550nAr-m550uAr-m620nAr-m620uAr-m700nAr-m700u

Table of Contents