Specifications

Dimensions:
Input Voltage:
Current:
Operating temperature:
Storage temperature:
Humidity:
Altitude:
RF Features
Dual-band support for both the 800MHz cellular and 1.9GHz PCS bands.
Adheres to CDMA authentication as specified in CDMA 1X.
Support for IS-95A/B and CDMA 1X Release 0/A.
Parameter
Output Power
RX sensitivity (US Cell)
RX sensitivity (US PCS)

Data Encryption

The communicator uses 256 bit AES (Rijndael) encryption (which is required for certain government installations). The
AlarmNet-i AES Encryption Software Module Version 1.0 contained in the Honeywell products has NIST approval.
Listings for this approval can be found at http://csrc.nist.gov/groups/STM/cavp/documents/aes/aesval.html and search for
"Certificate number 979."

Remote Services Features

NOTE
Remote Access and Multi-Mode have not been evaluated by compliance agency.
Honeywell offers secure web based services that enable users to remotely monitor and control their security system.
These web services enable
users to:
Monitor and control their security system from a website
Receive e-mail and text message notifications of system events
Control the system and receive confirmations using text messages
Monitor and control IP video cameras
Dealers can enroll their customers for "Remote Services" by using the AlarmNet Direct website. Once enabled, the specific
programming fields associated with these features can be programmed into the communications device either remotely
using the AlarmNet Direct website or locally using the 7720P programming tool.
E-mail notification (Multi Mode) is intended as a convenience for the user, and does not replace Central Station reporting of
critical events (alarms, troubles, etc.).

Testing the System

After installation the security system should be tested. Refer to the control panel installation instructions for procedures
to test the entire system.
CDMA-X Installation and Setup Guide
4 x 7 x 1.75 inches
12VDC (powered via the ECP bus.)
Standby 40mA, Maximum Transmit 300mA
–20º to +55ºC, for compliance agency 0ºC to +49ºC
–40º to +70ºC
0 to 95% relative humidity, non-condensing
(for compliance agency 0% to 85%)
to 10,000 ft. operating, to 40,000 ft. storage
Min
Typical
+23dBm
+24dBm
- -
–107dBm
- -
–107dBm
Maximum
+25dBm
- -
- -
– 2 –