[S]
ECP
[T]
Test Msg Sent
[X]
Reset CPU Y/N
[Shift]
Registering ...
[↑]
(UP arrow)
[↓]
Enter PIN#
(DN arrow)
[0]
Force Server
Update?
Y/N
[ENTER]
Strt Prog Mode?
Y/N_

Central Station Messages

The following messages are sent to the Central Station by AlarmNet for the conditions listed below. NOTE: The control
panel sends its own general code (E353) for a trouble condition.
Alarm Condition
Power On / Reset (xx=device address)
ECP Supervision
Communication Path Supervision
Code Download Begin
Code Download End Successful
Code Download Failed
Test
CDMA-X Installation and Setup Guide
Program Mode
Flt
Displays either ECP mode or the zones if 4204 / two-4204 was chosen.
OK
Flt
Displays the communicator fault status.
OK = Normal, No fault.
G = No network connectivity over CDMA and fault time has expired.
g = No network connectivity over CDMA and fault time has NOT yet expired.
Test Alarm
Sends a Test alarm to AlarmNet. Functional for a registered communicator only. If
the device is not registered, a message is displayed indicating that the command
cannot be executed.
Reset the communicator.
Pressing [N] returns to normal mode.
Pressing [Y] resets the device.
Note, this resets the CPU and does not affect the programming.
Registration
Registers a programmed communicator with AlarmNet.
Registration with PIN for Replacement Module
Registers a replacement communicator with AlarmNet, once programmed, using the
existing PIN #.
Force Upload of Configuration File to Server
Pressing [Y] will force the device to upload its entire configuration file to the server.
Pressing [N] cancels the operation.
NOTE: If the communicator is not initialized when you enter this command, the
following screen will be displayed:
Cannot Upload
Try Later! _
Wait for the SIGNAL (green) LED to light, indicating the communicator has
completed its initialization, and try again.
Enter Program Mode
Press [Y] to enter program mode; otherwise, press [N].
Alarm Code
E339 C08xx
E355 C0000
E903 C0803
n/a
E904 C0803
5555 5555 9
ECP Mode
Restore Code
5551 5555 6
R355 C0000
5555 5515 5
R350 C0951
R903 C0803
5555 5555 9
– 19 –
4204 Modes
Alarm Code
Restore Code
5555 5535 5
5555 5553 5