Siemens SIPROTEC 7RW80 Manual page 229

Voltage and frequency protection
Hide thumbs Also See for SIPROTEC 7RW80:
Table of Contents

Advertisement

Addr.
Parameter
5529
LR1 after 81-2
5530
LR1 after 81-3
5531
LR1 after 81-4
5540
LR2
5541
LR2 Start
5542
LR2 Start
5543
LR2 Pickup
5544
LR2 t pickup
5545
LR2 Dropout
5546
LR2 t dropout
5547
LR2 t CB Close
5548
LR2 after 81-1
5549
LR2 after 81-2
5550
LR2 after 81-3
5551
LR2 after 81-4
5560
LR3
5561
LR3 Start
5562
LR3 Start
5563
LR3 Pickup
5564
LR3 t pickup
5565
LR3 Dropout
5566
LR3 t dropout
5567
LR3 t CB Close
5568
LR3 after 81-1
5569
LR3 after 81-2
5570
LR3 after 81-3
5571
LR3 after 81-4
5580
LR4
5581
LR4 Start
5582
LR4 Start
5583
LR4 Pickup
5584
LR4 t pickup
5585
LR4 Dropout
5586
LR4 t dropout
5587
LR4 t CB Close
SIPROTEC, 7RW80, Manual
C53000-G1140-C233-1, Release date 10.2010
Function
Setting Options
Load Restore
YES
NO
Load Restore
YES
NO
Load Restore
YES
NO
Load Restore
ON
Load Restore
OFF
Load Restore
40.00 .. 60.00 Hz
Load Restore
50.00 .. 70.00 Hz
Load Restore
0.02 .. 2.00 Hz
Load Restore
0 .. 10800 sec
Load Restore
0.00 .. 2.00 Hz
Load Restore
0 .. 10800 sec
Load Restore
0.01 .. 32.00 sec; 0
Load Restore
YES
NO
Load Restore
YES
NO
Load Restore
YES
NO
Load Restore
YES
NO
Load Restore
ON
Load Restore
OFF
Load Restore
40.00 .. 60.00 Hz
Load Restore
50.00 .. 70.00 Hz
Load Restore
0.02 .. 2.00 Hz
Load Restore
0 .. 10800 sec
Load Restore
0.00 .. 2.00 Hz
Load Restore
0 .. 10800 sec
Load Restore
0.01 .. 32.00 sec; 0
Load Restore
YES
NO
Load Restore
YES
NO
Load Restore
YES
NO
Load Restore
YES
NO
Load Restore
ON
Load Restore
OFF
Load Restore
40.00 .. 60.00 Hz
Load Restore
50.00 .. 70.00 Hz
Load Restore
0.02 .. 2.00 Hz
Load Restore
0 .. 10800 sec
Load Restore
0.00 .. 2.00 Hz
Load Restore
0 .. 10800 sec
Load Restore
0.01 .. 32.00 sec; 0
Default Setting
NO
Load restoration element 1 after 81-
2
NO
Load restoration element 1 after 81-
3
NO
Load restoration element 1 after 81-
4
OFF
Load restoration element 2
49.00 Hz
Load restoration elem. 2 start fre-
quency
59.00 Hz
Load restoration elem. 2 start fre-
quency
0.04 Hz
Load restoration element 2 Pickup
600 sec
Load restoration element 2 Pickup
time
0.02 Hz
Load restoration element 2 Dropout
60 sec
Load restoration element 2 Dropout
time
1.00 sec
Load restoration element 2 CB
Close time
NO
Load restoration element 2 after 81-
1
NO
Load restoration element 2 after 81-
2
NO
Load restoration element 2 after 81-
3
NO
Load restoration element 2 after 81-
4
OFF
Load restoration element 3
47.50 Hz
Load restoration elem. 3 start fre-
quency
57.50 Hz
Load restoration elem. 3 start fre-
quency
0.04 Hz
Load restoration element 3 Pickup
600 sec
Load restoration element 3 Pickup
time
0.02 Hz
Load restoration element 3 Dropout
60 sec
Load restoration element 3 Dropout
time
1.00 sec
Load restoration element 3 CB
Close time
NO
Load restoration element 3 after 81-
1
NO
Load restoration element 3 after 81-
2
NO
Load restoration element 3 after 81-
3
NO
Load restoration element 3 after 81-
4
OFF
Load restoration element 4
47.50 Hz
Load restoration elem. 4 start fre-
quency
57.50 Hz
Load restoration elem. 4 start fre-
quency
0.04 Hz
Load restoration element 4 Pickup
600 sec
Load restoration element 4 Pickup
time
0.02 Hz
Load restoration element 4 Dropout
60 sec
Load restoration element 4 Dropout
time
1.00 sec
Load restoration element 4 CB
Close time
Appendix
A.7 Settings
Comments
229