Bnc Ports; Installing/Removing Modules - Siemens RUGGEDCOM RSG2488 Installation Manual

Hide thumbs Also See for RUGGEDCOM RSG2488:
Table of Contents

Advertisement

RUGGEDCOM RUGGEDCOM RSG2488
Installation Guide
4.
Store the port in an ESD-safe bag or other suitable ESD-safe environment, free from moisture and stored at
the proper temperature (-40 to 85 °C or -40 to 185 °F).
Section 3.4

BNC Ports

The following BNC ports are available on the PTP module:
1
2
Figure 41: PTP Module
1. Sync LED
2. AM IN Port
Port
5. TTL IN Port
Inputs are controlled by RUGGEDCOM ROS and only one can be active at any time. For information about
activating an input, refer to the RUGGEDCOM ROS User Guide for the RSG2488.
The color of the Sync LED on the front panel of the PTP module indicates the status of the incoming timing
signal:
• Green – Signal locked
• Amber/Yellow – Holdover
• Red – Error
• Off – No signal detected
Section 3.5

Installing/Removing Modules

The following sections describe how to install and remove modules:
Section 3.5.1, "Installing Modules"
Section 3.5.2, "Removing Modules"
BNC Ports
3
5
4
6
3. TTL OUT Port
4. GPS IN
6. AM OUT Port
Port
AM IN
AM-level IRIG-B signal
input, software enabled
AM OUT
output, software enabled
TTL OUT
IRIG-B PWM or 1 PPS signal
output, software selectable
TTL IN
B PWM signal input
GPS IN
GPS antenna input
Chapter 3
Communication Ports
Function
IRIG-B AM signal
TTL-level IRIG-
31

Hide quick links:

Advertisement

Table of Contents
loading