8.3

Transferring Data Records

Overview
Transfer screen
Specifying source
and destination
Equipment Manual OP7, OP17
Release 04/99
A transfer screen offering the following functions is available for transferring
data records.
OP
PLC
Before a changed or newly set up data record in a recipe can become
effective in the PLC, it must first be transferred via data record transfer to
the PLC.
PLC
OP
Transfer the data record which is active in the PLC to the OP under a new
number and a new name.
OP
OP
Copy an already existing data record on the OP.
The transfer screen is called via Record
1
Source:
Juice
PLC:
3
Figure 8-2
Transfer screen (Example: OP7)
The data record numbers for the source data record and the destination data
record must be entered in the transfer screen.
The PLC data record is always "0" for both directions of transfer.
The OP data record must always be specified as a number > 0.
Transfer. It is shown below.
2
1
Dest.:
2
3
Accept
OP:
4
4
No. of the source data
record
No. of the destination data
record
Only with SIMATIC S5:
The recipe/data record active
in the PLC
Recipe number selected on
the OP