Delete Data - Siemens SIMOVERT OP1S Operating Instructions Manual

Operator panel
Hide thumbs Also See for SIMOVERT OP1S:
Table of Contents

Advertisement

OP1S Operator Control Panel

3.7 Delete data

With the "Delete data" function, the user can delete parameter sets stored in the OP1S,
thus, for example, creating space for new sets of parameters. Starting from the basic
menu, the "Delete data" function is selected with "Lower" or "Raise" and activated with
"P".
P
Ì
Î
MotionControl
Delete data
OP: Upread
*1909199701
OP: Download
MASTERDRIVES MC
#Delete data
PLUS
Example: Selection and activation of the "Delete data" function
One of the parameter sets stored in the OP1S must now be selected with "Lower" or
"Raise" (displayed in the second line). With "P", the selected ID is confirmed. The slave
ID can now be displayed with "Lower" or "Raise" (see section "Slave ID"). The "Delete
data" procedure can then be started with "P". After completion, the message "Data
deleted" appears and the display returns to the basic menu.
Siemens AG
477 459 4070 76 J AA-74
SIMOVERT MASTERDRIVES
Operating Instructions
13

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents