Siemens simatic hmi op7 Equipment Manual page 82

Operator panel
Table of Contents

Advertisement

8-8
Example of entering source and destination:
Source
Destina-
Description
tion
11
0
Source data record 11 is an existing data record on the OP and
is to become the active data record on the PLC (destination).
Source
Destina-
Description
tion
0
22
The source data record 0 is the active data record on the PLC
which is to appear on the OP (destination) after the transfer
under data record number 22.
If data record number 22 already exists, it can be overwritten
or not if requested.
OP
Source
Destina-
Description
tion
33
44
Source data record 33 is an already existing data record on the
OP which is to be copied as data record 44.
If data record number 44 already exists on the OP, it can be
overwritten or not if requested.
Note
Symbolic value entries in the input fields source and destination:
The data record numbers from data records already stored on the OP can be
taken from a data record selection list.
"PLC" stands for data record 0 in the selection list.
OP
PLC Transfer
PLC
OP Transfer
OP Transfer (i.e., copying)
Equipment Manual OP7, OP17
Release 04/99

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents