Specifications - Optex HX-40 Installation Instructions Manual

High mount outdoor detector
Table of Contents

Advertisement

11

SPECIFICATIONS

Model
Detection method
PIR Coverage
Distance limit
Detectable speed
Sensitivity
Power input
Current draw
Alarm period
Warm-up period
Alarm output
Tamper output
Trouble output
Aux input
LED indicator
RF Interference
Operating temperature
Environment humidity
Weatherproof
Mounting
Mounting height
Bracket adjust angle
Weight
Accessories
* Specifications and design are subject to change without prior notice.
HX-40
12 m (40 ft.) 85° wide / 94 zones
4 m, 5.5 m, 9 m, 12 m (13 ft, 18 ft, 30 ft, 40 ft.)
0.3 – 1.5 m/s (1 – 5 ft/s)
2.0°C (3.6°F) at 0.6 m/s
35 mA (max) at 12VDC
Approx. 60 sec(LED blinks)
Form C 28VDC 0.2A max
N.C. 28V DC, 0.1A max. N.C. open when cover removed.
N.C. 28V DC, 0.1A max
Red:Warm-up, Alarm
-20 – +60°C (-4 – +140°F)
Wall (Outdoor, Indoor)
2.5 - 3.0 m (8.3 - 10 ft.)
Vertical: ± 20° Horizon: ± 95°
Bracket, Hood, Area masking seal, Screw kit (3×10-2, 4×20-4)
-11-
HX-40 AM
Passive infrared
9.5 – 18VDC
40 mA (max) at 12VDC
2.0 ± 1 sec
N.C. 28V DC, 0.1A max
Red:Warm-up, Alarm, Trouble
No alarm 10 V/m
95% max
IP55
600 g (21.2 oz)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hx-40am

Table of Contents