2.
Remove the screws (x2) that secure the ASF Unit.
Figure 4-70. Removing ASF Unit (1)
3.
Release the guide pins (x3) of the Base Frame and the shaft (x1) of the ASF Unit,
and then remove the ASF Unit.
Guide Pin and Positioning Hole
Figure 4-71. Removing ASF Unit (2)
DISASSEMBLY/ASSEMBLY
Downloaded from
www.Manualslib.com
ASF Unit
2
1
C.B.P. 3x8, F/Zn-3C (6±1kgfcm)
ASF Unit
manuals search engine
A D J U S T M E N T
R E Q U I R E D
Dowel
Shaft
Disassembling Printer Mechanism
When installing the ASF Unit, be sure to align the guide pins
(x2) of the Base Frame with the positioning holes (x2) of the
ASF Unit shown in the
Figure
4-70.
When routing the PE Sensor cable, pay attention to the
following instructions.
Route the cable in the order given in
Make sure to face the blue line of the cable toward the Base
Frame.
PE Sensor Cable
Figure 4-72. Routing PE Sensor Cable
Check if there is no slack in the cable.
After removing/replacing the ASF Unit, be sure to perform the
specified adjustment. See
Chapter 5 " ADJUSTMENT"
(p.107)
After replacing the ASF Unit, be sure to perform the required
lubrication. See
Chapter 6 " MAINTENANCE" (p.116)