EPSON Stylus C110/C120/D120
Tighten the screws in the order given in
Follow the steps below to install the Extension Spring 10.99 to
the Upper Paper Guide.
1. Attach the one end of the Extension Spring 10.99 to the
hook of the Upper Paper Guide.
2. Attach the another end of the Extension Spring 10.99 to the
hook of the Main Frame with a longnose plier.
Extension Spring 10.99
Hook
Figure 4-62. Installing Extension Spring 10.99
Be sure to install the Grounding Spring referring to
4-49
and
After replacing the Main Frame, be sure to perform the
A D J U S T M E N T
R E Q U I R E D
specified adjustment. See
(p.107)
After replacing the Main Frame, be sure to perform the
specified lubrication. See
(p.116)
DISASSEMBLY/ASSEMBLY
Downloaded from
www.Manualslib.com
Figure
Hook
Figure
4-52.
Chapter 5 " ADJUSTMENT"
Chapter 6 " MAINTENANCE"
manuals search engine

4.5.13 CR Unit

4-60.
Part/Unit that should be removed before removing CR Unit
Upper Housing/Lower Housing/Main Board Unit/Left Frame/Panel Unit/Front
Frame/Right Frame/CR Motor/CR Scale/Hopper/Main Frame Assy./Printhead
Removal Procedure
1.
Remove the screw (x1) that secures the CR Scale Holder, and remove it.
2.
Move the CR Unit in the direction of the arrow to remove the unit.
Figure
Disassembling Printer Mechanism
CR Unit
C.B.S. 3x6, F/Zn-3C (8±1kgfcm)
Figure 4-63. Removing CR Unit (1)