EPSON Stylus C110/C120/D120
When installing the PF Motor, pay attention to the following
instructions.
Do not damage the PF Scale.
Insert the guide pins (x2) on the Base Frame into the
positioning holes (x2) of the PF Motor as shown in
4-49.
Route the PF Motor connector cable referring to the figure
below.
Figure 4-50. Routing PF Motor Connector Cable
Tighten the screws in the order given in
Follow the steps below to install the Grounding Spring.
1. Attach the larger U-shaped end of the Grounding Spring to
the PF Roller.
Figure 4-51. Attaching Grounding Spring (1)
DISASSEMBLY/ASSEMBLY
Downloaded from
www.Manualslib.com
PF Motor Connector Cable
71mm or more
Figure
Grounding Spring
PF Roller
Disassembling Printer Mechanism
manuals search engine
Figure
A D J U S T M E N T
R E Q U I R E D
4-49.
2. Pass the Grounding Spring along the inner side of the hook of
the Main Frame.
3. Ground the smaller U-shaped end of the Grounding Spring
with the undersurface of the frame for PF Motor.
Main Frame
PF Motor
Grounding Spring
Figure 4-52. Installing Grounding Spring (2)
After replacing the PF Motor, be sure to perform the specified
adjustment. See
Chapter 5 " ADJUSTMENT" (p.107)
Revision B
Hook
92