EPSON Stylus C110/C120/D120
When installing the PF Motor, pay attention to the following
instructions.
•
Do not damage the PF Scale.
•
Insert the guide pins (x2) on the Base Frame into the
positioning holes (x2) of the PF Motor as shown in
4-49.
•
Route the PF Motor connector cable referring to the figure
below.
Figure 4-50. Routing PF Motor Connector Cable
Tighten the screws in the order given in
Follow the steps below to install the Grounding Spring.
1. Attach the larger U-shaped end of the Grounding Spring to
the PF Roller.
Figure 4-51. Attaching Grounding Spring (1)
DISASSEMBLY/ASSEMBLY
Downloaded from
www.Manualslib.com
PF Motor Connector Cable
71mm or more
Figure
Grounding Spring
PF Roller
Disassembling Printer Mechanism
manuals search engine
Figure
A D J U S T M E N T
R E Q U I R E D
4-49.
2. Pass the Grounding Spring along the inner side of the hook of
the Main Frame.
3. Ground the smaller U-shaped end of the Grounding Spring
with the undersurface of the frame for PF Motor.
Main Frame
PF Motor
Grounding Spring
Figure 4-52. Installing Grounding Spring (2)
After replacing the PF Motor, be sure to perform the specified
adjustment. See
Chapter 5 " ADJUSTMENT" (p.107)
Revision B
Hook
92