Epson Stylus C110 Service Manual page 52

Color inkjet printer
Hide thumbs Also See for Stylus C110:
Table of Contents

Advertisement

EPSON Stylus C110/C120/D120
Occurrence timing
Detailed phenomenon
CR position
• Operation
Cover open error is indicated even though
the printer cover is closed.
• Anywhere
Occurrence timing
Detailed phenomenon
CR position
• Operation
An error is indicated on the LED and
STM.
• –
TROUBLESHOOTING
Downloaded from
www.Manualslib.com
Table 3-4. Check point for cover open error according to each phenomenon
Defective unit/
part name
Cover Open Sensor
Table 3-5. Check point for the Maintenance request according to each phenomenon
Defective unit/
part name
Waste Ink Pads
manuals search engine
Check point
1. Check if the Cover Open Sensor Connector Cable is
connected to CN4 on the Main Board.
Cover Open Sensor
Connector Cable
CN4
2. Check if the Cover Open Sensor Connector Cable is not
damaged.
3. Check if the Cover Open Sensor is not damaged.
Check point
---
Troubleshooting
Revision B
Remedy
1. Connect the Cover Open Sensor Connector
Cable to CN4 on the Main Board.
2. Replace the Upper Housing with a new one.
3. Replace the Upper Housing with a new one.
Remedy
1. Change the Waste Ink Pads and initialize the
Waste Ink Pad Counter. (Refer to
Chapter 5
"ADJUSTMENT"
(p.107).)
52