IBM N7800 Hardware And Service Manual page 69

Table of Contents

Advertisement

4. Create a freebsd/ subfolder, and then create image1/ and image2/
subdirectories inside freebsd/. The directory structure should resemble the
following:
x86_64/
freebsd/
image1/
image2/
5. Navigate to the folder containing the *.tgz file on the PC and click the *.tgz
file.
6. Extract the files to the following locations on the CompactFlash card:
v
freebsd/image1
v
freebsd/image2
7. Return to the open zip-file window that displays the contents of the *.tgz file
that you want to install.
8. Uncompress and untar, if necessary, the contents of the file named diags.tgz
to the root directory on the CompactFlash card.
This creates the directory structure for the diagnostics utilities and firmware.
9. Verify the directory structure on the CompactFlash card. The directory
structure should resemble the following:
x86_64/
freebsd/
image1/
image2/
diag/
firmware/
common/
firmware/
10. If the node or controller is in an HA pair and the partner took over the node,
copy the backup system configuration file, varfs.tgz, from the target node's
root volume.
Note: If the node or controller is a stand-alone system or in an HA pair where
the node was not taken over by the partner, skip this step and go to the next
step.
Chapter 5. Replacing N7000 series system devices
43

Advertisement

Table of Contents
loading

This manual is also suitable for:

N7600N7900N7700

Table of Contents