Parameter
Pulse frequency
Due to higher switching losses at increased frequencies, certain inverters may have their maximum
continuous current (100%) derated if the switching frequency is changed from the default value.
13-20
Function
Range
[default]
0 - 7
[rating
dependent]
[0]
ECO REFERENCE MANUAL
Description / Notes
Sets the pulse frequency (from 2 to 16 kHz)
and the PWM mode. If silent operation is not
absolutely necessary, the losses in the inverter
as well as the RFI emissions can be reduced
by selecting lower pulse frequencies.
0/1 = 16 kHz (230 V default)
2/3 = 8 kHz
4/5 = 4 kHz (400 V default)
6/7 = 2 kHz
Even numbers = normal modulation technique.
Odd numbers = lower loss modulation
technique used when operating mainly at
speeds above 5 Hz. (Not generally for fan
and pump applications)
Model
% of full load de-rating
MICROMASTER Eco
ECO1-75/3
ECO1-110/3
ECO1-150/3
ECO1-220/3
ECO1-300/3
ECO1-400/3
ECO1-550/3
ECO1-750/3
Model
% of full load de-rating
16 kHz
MIDIMASTER Eco
ECO1-550/2
60
ECO1-750/2
55
ECO1-1100/2
64
ECO1-1500/2
60
ECO1-1850/2
47
ECO1-2200/2
43
ECO1-1100/3
57
ECO1-1500/3
50
ECO1-1850/3
64
ECO1-2200/3
55
ECO1-3000/3
50
ECO1-3700/3
47
ECO1-4500/3
40
ECO1-750/4
75
ECO1-1100/4
55
ECO1-1500/4
39
ECO1-1850/4
64
ECO1-2200/4
55
16 kHz
8 kHz
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
8 kHz
4 kHz
90
100
90
100
90
100
100
100
80
100
79
100
90
100
83
100
90
100
75
100
90
100
88
100
75
100
100
100
100
100
75
100
90
100
75
100