Menu survey

Parameter
Function
Normal operation
Temperature (setpoint)
Thermostat
Differential
Max. limitation of setpoint setting
Min. limitation of setpoint setting
Adjustment of temperature indication
Temperature unit (°C/°F)
Correction of the signal from S4
Correction of the signal from S3 and S3B
Manual service, stop regulation, start regulation (-1, 0, 1)
Displacement of reference during night operation
Define thermostat function
1=ON/OFF, 2=Modulating
Definition and weighting, if applicable, of thermostat sen-
sors - S4% (100%=S4, 0%=S3)
Time between melt periods
Duration of melt periods
Temperature setting for thermostat band 2
use r01
S6
Correction of the signal from
Definition and weighting, if applicable, of thermostat sen-
sors
when night cover is on. (100%=S4, 0%=S3)
Heat function
Neutral zone between refrigeration and heat function
Time delay at switch between refrigeration and heat
function
Alarms
Delay for temperature alarm
Delay for door alarm
Delay for temperature alarm after defrost
High alarm limit for thermostat 1
Low alarm limit for thermostat 1
High alarm limit for thermostat 2
Low alarm limit for thermostat 2
High alarm limit for sensor S6 at thermostat 1
Low alarm limit for sensor S6 at thermostat 1
High alarm limit for sensor S6 at thermostat 2
Low alarm limit for sensor S6 at thermostat 2
S6 alarm time delay
With setting = 240 the S6 alarm will be omitted
Alarm time delay or signal on the DI1 input
Alarm time delay or signal on the DI2 input
Signal for alarm thermostat. S4% (100%=S4, 0%=S3)
Delay for S6 (product sensor alarm) after defrost
Delay for temperature alarm S3B
Compressor
Min. ON-time
Min. OFF-time
Time delay for cutin of comp.2
Defrost
: 0=Off, 1= EL, 2= Gas
Defrost method
Defrost stop temperature
Interval between defrost starts
Max. defrost duration
Displacement of time on cutin of defrost at start-up
Drip off time
Delay for fan start after defrost
Fan start temperature
28
Code
1
- - -
1
r01
1
r02
1
r03
1
r04
1
r05
1
r09
1
r10
1
r12
1
r13
1
r14
1
r15
1
r16
1
r17
1
. As differential
r21
1
r59
1
r61
r62
r63
A03
1
A04
1
A12
1
A13
1
A14
1
A20
1
A21
1
A22
1
A23
1
A24
1
A25
1
A26
1
A27
1
A28
1
A36
1
A52
1
A53
c01
1
c02
1
c05
d01
1
d02
1
d03
1
d04
1
d05
1
d06
1
d07
1
d08
1
Manual RS8GL302 © Danfoss 2016-03
EL-diagram page 12 or 13
2
3
4
5
6
7
8
9
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Factory
Min.-value Max.-value
10
setting
1
-50°C
50°C
2
1
0.1 K
20 K
2
1
-49°C
50°C
50
1
-50°C
49°C
-50
1
-10
10
0
1
0/°C
1/F
0/°C
1
-10 K
10 K
0
1
-10 K
10 K
0
1
-1
1
0
1
-50 K
50 K
0
1
1
2
1
1
0 %
100 %
100
1
0 hrs
10 hrs
1
1
0 min.
30 min.
5
1
-50°C
50°C
2
1
-10 K
10 K
0
0 %
100 %
100
0 K
50 K
2
0 min.
240 min.
0
1
0 min.
240 min.
30
1
0 min.
240 min.
60
1
0 min.
240 min.
90
1
-50°C
50°C
8
1
-50°C
50°C
-30
1
-50°C
50°C
8
1
-50°C
50°C
-30
1
-50°C
50°C
8
1
-50°C
50°C
-30
1
-50°C
50°C
8
1
-50°C
50°C
-30
1
0 min.
240 min.
240
1
0 min.
240 min.
30
1
0 min.
240 min.
30
1
0 %
100 %
100
1
0 min.
240 min.
90
1
0 min.
240 min.
90
0 min.
30 min.
0
0 min.
30 min.
0
0 sec
999 sec
5
1
0/Off
2/gAs
1/EL
1
0°C
50°C
6
1
0 hrs/Off
240 hrs
8
1
0 min.
360 min.
45
1
0 min.
240 min.
0
1
0 min.
60 min.
0
1
0 min.
60 min.
0
1
-50 °C
0 °C
-5
SW = 1.6x
Actual
setting
AK-CC 550B

Advertisement

Table of Contents
loading

Table of Contents