If there is a fault condition, always try to remove the cause first. If it is not a hardware failure, it usually
succeeds. For example high VSWR, high Input power, mistune of PA, high temperature, etc.
In the case of some hardware failure or if your power amplifier is not working properly, please contact
the manufacturer or your dealer.
Never try to change or move any part inside the amplifier except of tube or fuses. Substitution of
parts may void intrinsic safety!
Manufacturer's contacts:
WARNING!
OM POWER, s.r.o.
930 30 Báč 126
SLOVAKIA
Email: om-power@om-power.com
This is the situation, when problem with high
Input power persists. Safety circuits reacted
3 times, and then switched PA to STBY mode.
Permanent fault appears.
Type of supported TCVR and working
To return PA to the normal operation,
decrease Input power first, then reset fault
frequency are visible on the display.
status and go back to the OPER mode.
If resistor R1 or fuse F3 is damaged, safety
circuit stops starting of the PA and fault
message appears on the display. It is
necessary
to
replace
component.
Type of supported TCVR and working
frequency are visible on the display.
Fuse F3
Resistor R1
Type of supported TCVR and working
frequency are visible on the display.
AUTO LED is ON.
the
damaged
AUTO LED is ON.
AUTO LED is ON.