Download Print this page

Advertisement

Quick Links

Owner's Instruction and Operation Manual
Model Number:
SP500
Report Number: F22-771
Certified to ASTM E1509-2022 and
Certified to CAN/ULC S627:2023
Mobile Home / Transportable Building
Approved
* All Pictures In This Manual Are For Illustrative Purposes Only. Actual Product May Vary.
SAFETY NOTICE: If this heater is not properly installed, a house fire may result. For your
safety, follow the installation instructions. Never use make-shift compromises during the
installation of this heater. Contact local building or fire officials about permits, restrictions
and installation requirements in your area. NEVER OPERATE THIS PRODUCT WHILE
UNATTENDED.
CAUTION! Please read this entire manual before you install or use your new room
heater. Failure to follow instructions may result in property damage, bodily injury, or
even death. Improper Installation Will Void Your Warranty!
U.S. Environmental Protection Agency
Certified to comply with 2020 particulate
emissions standards.
© 2024 Breckwell Hearth, South Pittsburg, TN 37380
R
Save These Instructions In A Safe Place For Future Reference.
THIS MANUAL IS SUBJECT TO CHANGE WITHOUT NOTICE.
CALIFORNIA PROPOSITION 65 WARNING:
This product can expose you to chemicals including carbon
monoxide, which is known to the State of California to cause
cancer, birth defects, and/or other reproductive harm. For
more information, go to
PH. 423-403-4031
854155-2903N
www.P65warnings.ca.gov

Advertisement

loading
Need help?

Need help?

Do you have a question about the SP500 and is the answer not in the manual?

Questions and answers

Summary of Contents for Breckwell SP500

  • Page 1 State of California to cause emissions standards. cancer, birth defects, and/or other reproductive harm. For more information, go to www.P65warnings.ca.gov THIS MANUAL IS SUBJECT TO CHANGE WITHOUT NOTICE. © 2024 Breckwell Hearth, South Pittsburg, TN 37380 PH. 423-403-4031...
  • Page 2 / transportable building. Your stove is Certified to ASTM E1509-2022 and Certified to CAN/ULC S627:2023. This manual describes the installation and operation of the Breckwell, SP500 wood heater. This heater meets the 2020 U.S. Environmental Protection Agency’s crib wood emission limits for wood heaters sold after May 15, 2020. Under specific test conditions this heater has been shown to deliver heat at rates ranging from 10,609 to 24,676 Btu/hr.
  • Page 3 Your wood stove should be installed by a qualified installer only. An NFI qualified Installer can be found at; www.nficertified.org/public/find-an-nfi-pro/ For customer service, please contact your Breckwell dealer. COMMISSIONING CHECKLIST This checklist is to be completed in full by the qualified person who installs this unit. Keep this page for future reference.
  • Page 4 2. Unpack the top mount controls and ensure that the wiring harness shown is attached securely. 4. Secure the control panel to the top of the stove with two sheet metal screws. © 2024 Breckwell Hearth...
  • Page 5 The use of other components other than stated herein VENTED. could cause bodily harm, heater damage, and void your warranty. The manufacturer will not be held responsible for damage caused by the malfunction of a stove due to improper venting or installation. © 2024 Breckwell Hearth...
  • Page 6 You can purchase the 69FAK through your heater 8” 204 mm dealer. Installation instructions are supplied with the air U.S.A 6” 153 mm intake kit. Front to Stove 18” 458 mm Back to Flue 2” 51 mm © 2024 Breckwell Hearth...
  • Page 7 EXPLAINED IN THIS MANUAL, IT WILL NOT FUNCTION minimum or 36” (914 mm) above the roof line of the PROPERLY. mobile home / transportable building and must be installed using a certified ceiling fire stop and rain cap. © 2024 Breckwell Hearth...
  • Page 8 B. Minimum 1-foot (0.3m) clearance above any door or to 50%. All joints in the vent system must be fastened by window that opens. at least 3 screws, and all joints must be sealed with Hi- © 2024 Breckwell Hearth...
  • Page 9 (wall thimble sold separately). heater dealer should be able to provide you with a kit that 3. Install venting. will handle most of this installation, which will include a wall thimble that will allow the proper clearance through © 2024 Breckwell Hearth...
  • Page 10 (the illustration is only an example). Please conform to any local building codes or regulations having jurisdiction before you have a qualified installer Support proceed with this installation. Bracket 3” to 6” Pipe Adapter To Stove 3” PL Vent Clean Out Tee © 2024 Breckwell Hearth...
  • Page 11 “1”. the bar graph starting from heat range “1” to heat range • When room temperature drops below desired set-point “5”. the stove will ramp back up until it reaches the desired temperature. © 2024 Breckwell Hearth...
  • Page 12 1. Garbage; than pellets is not permitted. It will violate the building codes for which the stove has been approved and will void 2. Lawn clippings or yard waste; all warranties. The design incorporates automatic feed of © 2024 Breckwell Hearth...
  • Page 13 This control is necessary due to the varied the metal. Maintaining smaller fires will minimize this. Avoid burn characteristics of individual installations, different placing items on the stovetop during this period because the © 2024 Breckwell Hearth...
  • Page 14 A. To recognize an overheat situation in the stove and shut down the fuel feed or auger system. B. In case of a malfunctioning convection blower, the high- temperature thermodisc will automatically shut down the auger, preventing the stove from overheating. © 2024 Breckwell Hearth...
  • Page 15 Plate clean fly ash out of the heat exchanger. The cleanouts are located inside the cabinet doors, on the lower front corners of the heat exchanger. To access these clean outs, © 2024 Breckwell Hearth...
  • Page 16 The closed container of ashes should be placed on a chimney, disconnect the vent from the stove. noncombustible floor or on the ground, well away from all combustible materials, pending final disposal. If the ashes are disposed of by burial in soil or otherwise locally © 2024 Breckwell Hearth...
  • Page 17 Empty & power motors should be inspected monthly to make sure season) Vacuumed they are free of animal hair build up. Animal hair build up in blowers can result in poor performance or unforeseen safety hazards. © 2024 Breckwell Hearth...
  • Page 18 Other information that may be needed would be the part number and part description of the item(s) in question. Part numbers and descriptions can be found in the “Repair Parts” section of this manual. Once this information has been gathered you can contact your Breckwell dealer or visit www.Breckwell.com Model Information Model Number Dealer’s Name...
  • Page 19 If the other items check out OK, replace the high limit switch. ATTENTION: THIS WOOD HEATER NEEDS PERIODIC INSPECTION AND REPAIR FOR PROPER OPERATION. IT IS AGAINST FEDERAL REGULATIONS TO OPERATE THIS WOOD HEATER IN A MANNER INCONSISTENT WITH OPERATING INSTRUCTIONS IN THIS MANUAL. © 2024 Breckwell Hearth...
  • Page 20 If you hear a click, the air switch is working. BE CAREFUL TOO MUCH VACUUM CAN DAMAGE THE AIR SWITCH. © 2024 Breckwell Hearth...
  • Page 21 The control board is not sending power to the POF There should be a 5-volt (approximately) current going to the POF thermodisc or other auger system components. thermodisc after the stove has been on for 10 minutes. © 2024 Breckwell Hearth...
  • Page 22 Remove the auger motor from the auger shaft and try to run the unit. The auger motor has failed. If the motor will turn the shaft is jammed on something. If the motor will not turn, the motor is bad. © 2024 Breckwell Hearth...
  • Page 23 Circuit board malfunction. is fine. If there is NOT power being sent to the blower when it shuts off during operation, then you have a bad control board. © 2024 Breckwell Hearth...
  • Page 24 Check to see if a surge protector is being used on the stove. If not, recommend one to the consumer. High limit switch is malfunctioning. If the other items check out okay, replace the high limit switch. © 2024 Breckwell Hearth...
  • Page 25 Bad Pellets. (Applies to GLASS “SOOT’S” UP AT A might also want to try a brand that is made from a different type VERY FAST RATE Only) of wood (softwood vs. hardwood). Different woods have different characteristics when being burned. © 2024 Breckwell Hearth...
  • Page 26 (not shown) 80709 Room Blower IN ORDER TO MAINTAIN WARRANTY, COMPONENTS MUST BE REPLACED USING ORIGINAL MANUFACTURERS PARTS PURCHASED THROUGH YOUR DEALER OR DIRECTLY FROM THE APPLIANCE MANUFACTURER. USE OF THIRD PARTY COMPONENTS WILL VOID THE WARRANTY. © 2024 Breckwell Hearth...
  • Page 27 WIRING DIAGRAM 7.5A 250V FUSE 1.25A 250V FUSE ENSURE THE WIRES ARE CONNECTED TO THE BOTTOM TWO PRONGS OF THE HOPPER SWITCH AS SHOWN. CORRECT WRONG © 2024 Breckwell Hearth...
  • Page 28 Engineer Name: _________________________________ Engineer Name: _________________________________ License No.: _____________________________________ License No.: _____________________________________ Company: ______________________________________ Company: ______________________________________ Telephone No.: __________________________________ Telephone No.: __________________________________ Stove Inspected: Chimney Swept: Stove Inspected: Chimney Swept: Items Replaced: __________________________________ Items Replaced: __________________________________ © 2024 Breckwell Hearth...