Your Installer can assign an Identifier Number and Descrip-
tion to up to 500 Keys/Cards. The number will be recorded
in the Event Logger each time the Key/Card operates on
the System. The Digital Keys/Cards/Miniproxi can be pro-
grammed to operate on specific Partitions.
+
In this Manual, the word Reader refers to
ECLIPSE2, PROXI Readers and the PROXI of the
PREMIUM keypad .

The Reader LEDs

The ECLIPSE2 Key and PROXI Card Readers simplify
system control by replacing User Code PINs with high
Security Digital Keys or Cards. The Readers have 3
LEDs, this section describes how the LEDs will signal
the System status.
+
If the reader has been set to Compatibility with
EN50131, all the indicator lights will be switched off
at the end of the Exit time and Entry time periods.
n No Key/Card/Miniproxi at Reader
When no Digital Key/Card/Miniproxi is present at the Rea-
der, the LEDs will signal as shown in Table 6.
The Partitions that are not controlled by the Reader will not
affect the LEDs. If the configuration of the Armed Partitions
does not match either A or B Mode Arming (for example,
one of the Reader Partitions has been Armed via Keypad),
neither the Amber nor Green LED will turn ON.
+
The Installer can program the Reader LEDs to si-
gnal the System status at all times, or alternatively,
only in response to a Valid Key/Card (LEDs OFF
when no Key/Card/Miniproxi is present).
n Key/Card/Miniproxi at Reader
When a Key/Card/Miniproxi is present at the Reader
(near the sensitive field), the LEDs will signal as fol-
lows.
a) Fast Blinking on 1 LED - Before Arming the Parti-
tions, the Control panel will check the status of the
Unbypassed (ON) and Instant Zones. If a Zone is 'Viola-
ted' (e.g. door or window open), the LED, associated
LED
Status
All of the Reader Partitions are Disarmed
OFF
At least one of the Reader Partitions is Armed
ON
At least one Alarm or Tamper event has been detected on one of the Reader Partitions
Slow
RED
and ALL the Reader Partitions are Disarmed
Blinking
At least one Alarm or Tamper event has been detected on one of the Reader Partitions
Fast
and AT LEAST ONE of the Reader Partitions is Armed
Blinking
The Reader Partitions are Armed in A Mode
ON
YELLOW
The Armed/Disarmed status of the Reader Partitions does not match A Mode
OFF
The Reader Partitions are Armed in B Mode
ON
GREEN
The Armed/Disarmed status of the Reader Partitions does not match B Mode
OFF

KYO320

TABLE 6 - LED Status with no Key/Card at Reader
USING DIGITAL KEYS AND CARDS
with the selected Arming Mode, will blink quickly. If this
occurs, DO NOT ARM the System, as Arming will trig-
ger a False Alarm.
+
It takes the Control panel about 2 seconds to check
all the Zones.
+
False Alarms can be stopped by simply Disarming
the system (refer to "Digital Key/Card Reader ope-
rations" in this section). If you accidentally trigger
an Alarm, call the Central Station to prevent the
operator from taking unnecessary action.
+
If, when you Arm the system, the Control panel de-
tects Autobypassable zones in Alarm status, it will
bypass them automatically. In this
Alarms will not be triggered, however, Bypassed
zones will be UnBypassed automatically when the-
ir Partitions are next disarmed.
b) Fast Blinking on all 3 LEDs - This will occur when a
False Key/Card/Miniproxi is present at the Reader (
near the sensitive field).
c) Slow Blinking on all 3 LEDs - This Mode will allow
you to restore the previous setting (reset the Arming
Mode that was active before the SAT Key/Card/Mini-
proxi was near the sensitive field). To Reset: hold the
SAT Key/Card/Miniproxi near the sensitive field) Rea-
der until the 3 LEDs start to blink slowly, the previous
setting will be restored when you leave the Key from the
sensitive field of the reader.
d) Red LED ON - The System will Arm when you leave
the Key/Card/Miniproxi from the sensitive field of the
Reader.
e) Amber LED ON - The System will Arm in A Mode
when you leave the Key/Card/Miniproxi from the sensi-
tive field of the Reader.
f) Green LED ON - The System will Arm in B Mode
when you leave the Key/Card/Miniproxi from the sensi-
tive field of the Reader.
Meaning