4.12 Display messages

Error No. + Picture
TX0113
TX0114
TX0115
TX0116
TX0117
TX0118
TX0119
TX0125
© 2011 by Thermoplan, subject to change
Operating instructions BW3-CTMC + BW3-RF
Text
Piston error
Bean hopper empty
(right-hand side)
Flow error
Overtime error
Change water filter
Interface error
Powder error
Waterflow error
Cause
Piston cannot move
The right bean hopper is
empty
No water flow
Machine cannot dispense
properly, too little water
The programmed amount
of water has flown
through the water filter
Interface is active:
- Wrong interface chosen
- No interface connected
Grinders blocked
No water flow or flow-
meter defective
Clearing
1. Try dispensing again
2. Rinse the machine
3. Call service
Refill coffee beans on the
right bean hopper
1. Open water connection
2. Empty grounds drawer
3. Rinse the machine
4. Call service
1. Try to dispense again
2. Call service
Change water filter.
Check interface settings
or turn them to „off"
1. Empty grounds drawer
+ vacuum grinders (p. 20)
2. Rinse machine
3. Call service
1. Open water connection
2. Empty grounds drawer
3. Rinse the machine
4. Call service