RS232 Settings

The section of the Settings page shown in
Table
3.
RS232 Settings
FIG. 23
Settings Page: RS232 Settings
TABLE 3
Option
RS232 Baud Rate
RS232 Data Bits
RS232 Parity
RS232 Stop Bits

Network Setup Section

The Network Setup section of the Settings page is shown in
Network Setup Section
FIG. 24
Settings Page: Network Setup Settings
TABLE 4
Option
IP Mode
IP address
Netmask
Gateway address
N2151/N2251 User Manual
Figure 23
is displayed when you click the RS232 Settings link. Options are described in
Description
Select the appropriate baud rate for the RS232 serial interface. Default is 9600.
Select the appropriate data bit count for the RS232 serial interface. Default is 8.
Select the appropriate parity for the RS232 serial interface. Default is no parity (none).
Select the appropriate number of stop bits for the RS232 serial interface. Default is 1.
Description
Configure the IP address mode. When set to AUTO IP,
an IP Address in the range of 169.254.xxx.xxx with
Netmask of 255.255.0.0 and Gateway address of
169.254.1.1 will be automatically assigned to the
N2151 Encoder by the control software. When set to
DHCP, an IP Address in the range of the DHCP server on
the network will be automatically assigned to the
N2151 Encoder. When set to STATIC, an IP address,
Netmask, and Gateway address must be manually
entered.
View the current IP address of the N2151 Encoder.
When in STATIC mode, enter a new IP address into this
field.
View the current Netmask of the N2151 Encoder. When
in STATIC mode, enter a new Netmask into this field.
View the current Gateway address of the N2151
Encoder. When in STATIC mode, enter a new Gateway
address into this field.
Figure
24. Options are described in
Notes
DHCP is the default setting. However, using DHCP
beyond initial setup is generally not recommended. If
the device is set to DHCP and fails to receive an
address from the DHCP server in time, it will revert
back to the AUTO IP Address (169.254.xxx.xxx) until
the unit is rebooted.
No warnings are provided regarding improper
addressing/subnetting. Be very careful to follow
standardized network protocol guidelines when
adjusting these settings.
No warnings are provided regarding improper
addressing/subnetting. Be very careful to follow
standardized network protocol guidelines when
adjusting these settings.