Outdoor unit installation

Outdoor installation precaution
• Install the outdoor unit on a rigid base to prevent
increasing noise level and vibration.
• Determine the air outlet direction where the
discharged air is not blocked. In the case that the
installation place is exposed to strong wind such as
a seaside, make sure the fan operating properly by
putting the unit lengthwise along the wall or using a
dust or shield plates.
• Specially in windy area, install the unit to prevent the
admission of wind. If need suspending installation,
the installation bracket should accord with technique
requirement in the installation bracket diagram.
• The installation wall should be solid brick, concrete
or the same intensity construction, or action store in
force, damping supporting should be taken. The
connection between bracket and wall, bracket and
the air conditioner should be firm, stable and
reliable.
• Be sure there is no obstacle which block radiating
air.
Settlement of outdoor unit
• Anchor the outdoor unit with a bolt and nut
10 or
8 tightly and horizontally on a concrete
Φ
Φ
or rigid mount.
Outdoor unit dimension
mm(L1xHxW1)
760x590x285
845x700x320
900x860x315
990x965x345
Mounting dimensions
L2(mm)
W2(mm)
530
290
560
335
590
333
624
366