INSTALATION INSTRUCTIONS

1. Wall-mounted type

Selecting installation place

Rea d comp le te ly, th en fo ll ow st ep by st ep.
Indoor unit
Do not expose the indoor unit to heat or steam.
Select a place where there are no obstacles in front or
around the unit.
Make sure that condensation drainage can be conveniently
routed away.
Do not install near a doorway.
Ensure that the space on the left and right of the unit is more
than 12cm.
Use a stud finder to locate studs to prevent unnecessary damage to the wall.
The indoor unit should be installed on the wall at a height of 2.3 metres or more from the floor.
The indoor unit should be installed allowing a minimum clearance of 15cm from the ceiling.
Any variations in pipe length will/may require adjustment to refrigerant charge.
There should not be any direct sunlight. Otherwise, the sun will fade the plastic cabinet and affect its
appearance. If unavoidable, sunlight prevention should be taken into consideration.
Outdoor unit
If an awning is built over the outdoor unit to
prevent direct sunlight or rain exposure, make sure
that heat radiation from the condenser is not
restricted.
Ensure that the clearance around the back of the
unit is more than 30cm and left side is more than
30cm. The front of the unit should have more than
200cm of clearance and the connection side (right
side) should have more than 60cm of clearance.
Do not place animals and plants in the path of the
air inlet or outlet.
Take the air conditioner weight into account and select a place where noise and vibration will not be an
issue.
Select a place so that the warm air and noise from the air conditioner do not disturb neighbors.

Rooftop installation:

If the outdoor unit is installed on a roof structure, be sure to level the unit.
Ensure the roof structure and anchoring method are adequate for the unit location.
Consult local codes regarding rooftop mounting.
If the outdoor unit is installed on roof structures or external walls, this may result in excessive noise and
vibration, and may also be classed as a non serviceable installation.