Panasonic Digital Fiber Sensor FX-301 Specification Sheet page 57

Panasonic digital fiber sensor specification sheet
Table of Contents

Advertisement

FX-301-F
ORDER GUIDE
End plates
End plates are not supplied with the amplifier. Please order it separately when the amplifiers are mounted in cascade.
Appearance
OPTIONS
Designation
Model No.
MS-DIN-2
Amplifier mounting bracket
Fiber sensor amplifier
FX-MB1
protection seal
SPECIFICATIONS
Type
Model No.
Item
Applicable fibers
Supply voltage
Power consumption
NPN open-collector transistor
Output
Output operation
Leak setting (F7 mode): OFF with detection of leak, Liquid setting (F9 mode): Using the jog switch, choose the signal OFF condition between absence of liquid and presence of liquid.
Short-circuit protection
Response time
Sensitivity setting
Operation indicator
Model indicator
MODE indicator
Digital display
Fine sensitivity adjustment function
Timer function
Ambient temperature
Ambient humidity
Ambient illuminance
EMC
Voltage withstandability
Insulation resistance
Vibration resistance
Shock resistance
Emitting element
Material
Connecting method
Cable extension
Weight
Notes: 1) When detecting leak (output OFF) during leak setting (F7 mode), since the sensor flashes the emitted light, only the response action for turning the signal back to ON is delayed (1 sec. approx.).
Notes:
2) The voltage withstandability and the insulation resistance values given in the above table are for the amplifier only.
Notes:
3) The cable for amplifier connection is not supplied as an accessory. Make sure to use the optional quick-connection cable given below.
Main cable (3-core): CN-73-C1 (cable length 1 m
Sub cable (1-core): CN-71-C1 (cable length 1m
520
Model No.
When cascading multiple amplifiers, or when it moves depending
on the way it is installed on a DIN rail, these end plates ensure
that all amplifiers are mounted together in a secure and fully
MS-DIN-E
connected manner.
Two pcs. per set
Description
Mounting bracket for amplifier
10 sets of 2 communication window seals and 1 connector seal
Communication window seal:
It prevents malfunction due to transmission signal from another
amplifier, as well as, prevents effect on another amplifier.
Connector seal:
It prevents contact of any metal, etc., with the pins of the quick-
connection cable.
NPN output
FX-301-F
Normal operation: 960 mW or less (Current consumption 40 mA or less at 24 V supply voltage)
ECO mode: 600 mW or less (Current consumption 25 mA or less at 24 V supply voltage)
Maximum sink current: 100 mA (50 mA, if five, or more,
amplifiers are connected in cascade.)
Applied voltage: 30 V DC or less (between output and 0 V)
Residual voltage: 1.5 V or less [at 100 mA (50 mA, if five, or
more, amplifiers are connected in cascade.) sink current]
Green LED [lights up during liquid setting (F9 mode)]
RUN: Green LED, TEACH ALL ADJ DISP OUT: Yellow LED
Delay timer [used only for liquid setting (F9 mode)] (Timer setting selectable from 10 ms, 100 ms, 1,000 ms, and none)
0 to
50 C
32 to
122 F
(No dew condensation), Storage:
Sunlight: 10,000 ?x at the light-receiving face, Incandescent light: 3,000 ?x at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure (Note 2)
20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure (Note 2)
10 to 150 Hz frequency, 0.75 mm
2
98 m/s
acceleration (10 G approx.) in X, Y and Z directions for five times each
Enclosure: Heat-resistant ABS, Case cover: Polycarbonate, Switch: Acrylic
Extension up to total 100 m
3.281
ft), CN-73-C2 (cable length 2 m
3.281
ft), CN-71-C2 (cable length 2 m
Description
Amplifier mounting
bracket
MS-DIN-2
FD-F7 series, FT-F9 series
12 to 24 V DC
10 % Ripple P-P 10 % or less
PNP open-collector transistor
Maximum source current: 100 mA (50 mA, if five, or
more, amplifiers are connected in cascade.)
Applied voltage: 30 V DC or less (between output and
Residual voltage: 1.5 V or less [at 100 mA (50 mA, if five, or
more, amplifiers are connected in cascade.) source current]
Incorporated
250!s or less (Note 1)
Individual teaching / Collective teaching
Orange LED (lights up when the output is ON)
4 digit red LED display
Incorporated
(If 8 to 16 units are connected in cascade: 0 to
20 to
70 C
4 to
158 F
35 to 85 % RH, Storage: 35 to 85 % RH
EN 50081-2, EN 50082-2, EN 60947-5-2
0.030 in
amplitude in X, Y and Z directions for two hours each
Red LED (modulated)
Connector (Note 3)
328.084 ft
is possible with 0.3 mm
20 g approx.
6.562
ft), CN-73-C5 (cable length 5 m
6.562
ft), CN-71-C5 (cable length 5 m
08/2005
Fiber sensor amplifier
protection seal
FX-MB1
PNP output
FX-301P-F
45 C
32 to
113 F
2
, or more, cable.
16.404
ft)
16.404
ft)
V)

Advertisement

Table of Contents
loading

Table of Contents