Panasonic Digital Fiber Sensor FX-301 Specification Sheet page 33

Panasonic digital fiber sensor specification sheet
Table of Contents

Advertisement

FX-301
PRECAUTIONS FOR PROPER USE
Fiber
Mounting
The tightening torque must not exceed the values given
below.
Mounting with a nut (threaded head type)
M14
Mounting with a set screw
Tightening torque: 0.29 N m or less
Fibers for which the tightening section has been specified
should be fixed at ?mm from the tightening section tip.
(
However, for FT-K8, FT-KV8, FT-WKV8 and FT-V10 '?'
indicates the range over which tightening cannot be done.
FT-PS1
FD-E12
FT-V22
<
>
FT-K8, FT-KV8, FT-WKV8, FT-V10
FT-41, FD-V41
FT-SFM2SV2
FD-EG1
FT-WV42
FD-WV42
FD-SFM2SV2
FT-KV8, FT-WKV8
FT-V10
FT-K8
Notes 1): Excluding the sleeve.
Notes
100
Tightening torque
M3
0.39 N·m
0.58 N·m
(
350 °C
662 °F
heat-resistant fiber and
M4
FT-H20W-M : 0.98 N m,
FD-H35-20S: 0.58 N m
0.98 N·m
M5
(
350 °C
662 °F
heat-resistant
M6
fiber: 1.96 N m
1.47 N m
(
FT-SFM2L: 0.19 N m
FT-H20W-M : 0.49 N m
? (mm in) Tightening torque
3
0.118
0.1 N m
4
0.157
0.29 N m
(Note 1)
10
0.394
0.19 N m
10
0.394
0.29 N m
15
0.591
0.29 N m
7
0.276
0.34 N m
13
0.512
0.3 N m
12
0.472
2): When installing, make sure to use
screws smaller than the fiber
diameter.
Mounting array fiber
Using M3 screws, the tightening
torque should be 0.58 N m or less.
)
Mounting FD-L4
Using M2.6 (length
)
12 mm
0.472
in)
screws with washers
(accessor y),
the
tightening torque
should be 0.3 N m
or less.
Mounting FD-WL41 / FD-L41 and FD-WL42 / FD-L42
)
Using M3 counter-
sunk head screws,
the tightening torque
should be 0.3 N m
or less.
)
Mounting FD-L43
Using M3 counter-
sunk head screws,
the tightening torque
should be 0.3 N m
or less.
08/2005
<
>
FD-WL41 / FD-L41
<
>
FD-WL42 / FD-L42

Advertisement

Table of Contents
loading

Table of Contents