Download Print this page
Panasonic FX-301-F Instruction Manual

Panasonic FX-301-F Instruction Manual

Digital fiber sensor for leak / liquied detection fiber

Advertisement

Quick Links

Digital Fiber Sensor For Leak / Liquied Detection Fiber
FX-301(P)-F
Thank you very much for purchasing Panasonic products.
Please read this Instruction Manual carefully and thoroughly for the correct
and optimum use of this product.
Kindly keep this manual in a convenient place for quick reference.
Never use this product as a sensing device for personnel protection.
In case of using sensing devices for personnel protection, use products
which meet laws and standards, such as OSHA, ANSI or IEC etc., for
personnel protection applicable in each region or country.
1
PART DESCRIPTION
Operation indicator
Model indicator (Green)
(Orange)
MODE indicator / RUN (Green)
MODE indicator / TEACH (Yellow)
MODE indicator / ALL (Yellow)
Digital display (Red)
2SHUDWLQJ SRUWLRQ!
MODE key
Press
Press
Used for mode se-
lection or cancella-
U s e d t o s e l e c t
tion during setting.
each item.
(Note)
Note: When MODE key is pressed for 1 sec., or more, the sensor returns to the RUN mode.
(in MAIN mode only)
2
MOUNTING
+RZ WR PRXQW WKH DPSOL¿HU
1. Fit the rear part of the mounting section of the
DPSOL¿HU RQ D PP ZLGWK ',1 UDLO
2. Press down the rear part of the mounting section
RI WKH XQLW RQ WKH PP ZLGWK ',1 UDLO DQG ¿W WKH
front part of the mounting section to the DIN rail.
+RZ WR UHPRYH WKH DPSOL¿HU
 3XVK WKH DPSOL¿HU IRUZDUG
 /LIW XS WKH IURQW SDUW RI WKH DPSOL¿HU WR UHPRYH LW
1RWH 7DNH FDUH WKDW LI WKH IURQW SDUW LV OLIWHG ZLWKRXW SXVKLQJ WKH DPSOL¿HU IRUZDUG WKH KRRN
on the rear portion of the mounting section is likely to break.
+RZ WR FRQQHFW WKH ¿EHU FDEOH
Make sure to connect the fiber attachment (FX-AT4), enclosed with the
¿EHU WR WKH ¿EHUV
5HIHU WR WKH ,QVWUXFWLRQ 0DQXDO RI WKH ¿EHU DWWDFKPHQW IRU WKH FRQQHFWLQJ
method.
 6QDS WKH ¿EHU ORFN OHYHU GRZQ WLOO LW VWRSV FRP-
pletely.
 ,QVHUW WKH ¿EHU FDEOHV ZLWK WKH ¿EHU DWWDFKPHQW
(FX-AT4) slowly into the fiber inlet till it stops
(Note).
 5HWXUQ WKH ¿EHU ORFN OHYHU WR WKH RULJLQDO SRVL-
tion, till it stops.
1RWH 7DNH FDUH WKDW LQ FDVH WKH ¿EHU FDEOHV DUH QRW LQVHUWHG WR D SRVLWLRQ ZKHUH WKH\ VWRS
the sensing becomes unstable.
INSTRUCTION MANUAL
MJE-FX301F No.0034-46V
MODE indicator / ADJ (Yellow)
MODE indicator / DISP (Yellow)
MODE indicator
MODE key
OUT (Yellow)
Jog switch
Jog switch
Turn to "+" side
Turn to"–" side
Used to enter each item.
2
35mm width DIN rail
1
2
3
1
Fiber lock
lever
2
Fiber attachment
Fiber
3
CONNECTION
Make sure to connect or disconnect the quick-connection cable in the
power supply off condition.
&RQQHFWLRQ PHWKRG
1. Holding the connector of the quick-connection
cable, align its release lever with the groove
DW WKH WRS SRUWLRQ RI WKH DPSOL¿HU FRQQHFWRU
2. Insert the connector till a click is felt.
'LVFRQQHFWLRQ PHWKRG
1. Pressing the release lever at the top of the
quick-connection cable connector, pull out the
connector.
Note: Take care that if the connector is pulled out without pressing the release lever, the re-
lease lever may break. Do not use a quick-connection cable whose release lever has
broken. Further, do not pull by holding the cable, as this can cause a cable-break.
7HUPLQDO DUUDQJHPHQW GLDJUDP!
1
3
2
4
CASCADING AMPLIFIERS
Make sure that the power supply is off while adding or removing the am-
SOL¿HUV
Make sure to check the allowable ambient temperature, as it depends
RQ WKH QXPEHU RI DPSOL¿HUV FRQQHFWHG LQ FDVFDGH
,Q FDVH WZR RU PRUH DPSOL¿HUV DUH FRQQHFWHG LQ FDVFDGH PDNH VXUH WR
mount them on a DIN rail.
:KHQ WKH DPSOL¿HUV PRYH RQ WKH ',1 UDLO GHSHQGLQJ RQ WKH DWWDFKLQJ
FRQGLWLRQ RU WKH DPSOL¿HUV DUH PRXQWHG FORVH WR HDFK RWKHU LQ FDVFDGH
fit them between the optional end plates (MS-DIN-E) mounted at the
two ends.
8S WR PD[LPXP  DPSOLILHUV FDQ EH DGGHG WRWDO  DPSOLILHUV FRQ-
nected in cascade).
When connecting more than two amplifiers in cascade, use the sub
cable (&1& ) as the quick-connection cable for the second ampli-
¿HU RQZDUGV
:KHQ FRQQHFWLQJ DPSOL¿HUV QRW FORVH WR HDFK RWKHU LQ SDUDOOHO EH VXUH
to mount the optional end plate (MS-DIN-E) at both sides of each ampli-
¿HU RU DI¿[ WKH FRPPXQLFDWLRQ ZLQGRZ VHDO RI WKH DFFHVVRU\ DPSOL¿HU
protection seal (FX-MB1) to the communication windows.
Communication function is different between this amplifier and other
1
GLJLWDO ¿EHU DPSOL¿HU ,I WKRVH DPSOL¿HUV DUH PRXQWHG LQ FDVFDGH DI¿[
the communication window seal of the accessory amplifier protection
seal (FX-MB1) to the communication windows.
In case of cascading, wait for 10 minutes, or more, to use the teaching
function after the power is switched on.
)RU PRXQWLQJ DQG UHPRYLQJ WKH DPSOL¿HU UHIHU WR ³
&DVFDGLQJ PHWKRG
 0RXQW WKH DPSOL¿HUV RQH E\ RQH
RQ WKH PP ZLGWK ',1 UDLO
 6OLGH WKH DPSOL¿HUV QH[W WR HDFK
other, and connect the quick-
connection cables.
3. Mount the optional end plates
(MS-DIN-E) at both the ends to
KROG WKH DPSOL¿HUV EHWZHHQ WKHLU
ÀDW VLGHV
 7LJKWHQ WKH VFUHZV WR ¿[ WKH HQG
plates.
'LVPDQWOLQJ PHWKRG
1. Loosen the screws of the end
plates.
2. Remove the end plates.
3. Slide the amplifiers and remove
them one by one.
Quick-connection
cable
Terminal No.
Terminal name
1
+V
2
0V
3
Output
Main cable
(&1& ) (Optional)
End plate
(MS-DIN-E) (Optional)
Groove
Release
lever
Release
lever
MOUNTING."
Sub cable
(&1& ) (Optional)
Slide
End plate
(MS-DIN-E) (Optional)
Slide

Advertisement

loading

Summary of Contents for Panasonic FX-301-F

  • Page 1 Release DW WKH WRS SRUWLRQ RI WKH DPSOL¿HU FRQQHFWRU lever Thank you very much for purchasing Panasonic products. 2. Insert the connector till a click is felt. Please read this Instruction Manual carefully and thoroughly for the correct and optimum use of this product.
  • Page 2: Operation Procedure

    I/O CIRCUIT DIAGRAMS INDIVIDUAL TEACHING MODE 131 RXWSXW W\SH! The sensitivity selection function is set to the automatic sensitivity setting Terminal No. Color code of quick-connection cable “ ” at the time of factory shipment. In case sensitivity selection set- ting is done, make sure to carry out “teaching”...
  • Page 3 THRESHOLD VALUE FINE ADJUSTMENT MODE SENSITIVITY SELECTION FUNCTION When MODE indicator / ADJ (yellow) lights up, the set threshold value If Jog switch is pressed for 3 sec., or more, when MODE indicator / ADJ FDQ EH ¿QH DGMXVWHG \HOORZ OLJKWV XS WKH VHQVLWLYLW\ FDQ EH ¿[HG WR ORZ VHQVLWLYLW\ RU KLJK VHQ- sitivity, or set to automatic sensitivity.
  • Page 4: Specifications

    EEPROM is adopted to this product. It is not possible to conduct teach- About our sale network, please visit our website. ing 100 thousand times or more, because of the EEPROM's lifetime. PRINTED IN JAPAN © Panasonic Industrial Devices SUNX Co., Ltd. 2012...

This manual is also suitable for:

Fx-301p-f