FIBER OPTIONS
Lens (For thru-beam type fiber)
Designation
Model No.
Expansion
FX-LE1
lens
(Note 1)
Super-
expansion
FX-LE2
lens
(Note 1)
Side-
FX-SV1
view
lens
Expansion
lens for
vacuum
FV-LE1
fiber
(Note 1)
Notes: 1) Be careful when installing the thru-beam type fiber equipped with the expansion lens, as the beam envelope becomes narrow and alignment is difficult.
Especially when installing a fiber with many cores (sharp bending fibers and heat-resistant glass fiber) please be sure to use it only after you have adjusted it sufficiently.
Notes:
2) The sensing ranges are the values for red LED type amplifier. Please contact our office for details on sensing ranges for other types of amplifiers.
Notes:
3) The fiber cable length practically limits the sensing range to 3.500 mm
Lens (For reflective type fiber)
Designation
Model No.
Pinpoint
FX-MR1
spot lens
FX-MR2
Zoom lens
Finest spot
FX-MR3
lens
Finest spot
FX-MR6
lens
Zoom lens
FX-MR5
Side-view
(
)
type
Note: The sensing ranges are the values when used in combination with red LED type amplifier. Please contact our office for details on sensing distances for other types of amplifier.
Description
Increases the sensing range by 5 times or
more.
Ambient temperature:
60 to
350 C
76 to
662 F
Tremendously increases the sensing
range with large diameter lenses.
Ambient temperature:
60 to
350 C
76 to
662 F
Beam axis is bent by 90 .
Ambient temperature:
60 to
300 C
76 to
572 F
Sensing range increases by 15 times or
more.
Ambient temperature:
40 to
120 C
40 to
248 F
137.795 in
Pinpoint spot of "0.5 mm
"0.020
Applicable fibers: FD-WG4, FD-G4
Ambient temperature:
40 to
The spot diameter is adjustable from "0.7 mm
"0.028 in
to "2 mm
"0.079 in
how much the fiber is screwed in.
Applicable fibers: FD-WG4, FD-G4
Ambient temperature: 40 to 70 C
Accessory: MS-EX-3 (mounting bracket)
Extremely fine spot of "0.3 mm
achieved.
Applicable fibers: FD-WG4, FD-G4, FD-EG1,FD-EG2,
FD-EG3, FD-G6X, FD-G6
Ambient temperature: 40 to
70 C
Extremely fine spot of "0.1 mm
achieved.
Applicable fibers: FD-WG4, FD-G4, FD-EG1,FD-EG2,
FD-EG3, FD-G6X, FD-G6
Ambient temperature: 20 to
60 C
FX-MR2 is converted into a side-view type and
can be mounted in a very small space.
Applicable fibers: FD-WG4, FD-G4
Ambient temperature: 40 to
70 C
08/2005
Sensing range (mm) [Lens on both sides] (Note 2)
Mode
LONG
Fiber
FT-B8
3,500
( Note 3 )
FT-FM2
3,500
( Note 3 )
FT-T80
3,500
( Note 3 )
FT-R80
3,500
( Note 3 )
FT-W8
3,500
( Note 3 )
FT-P80
3,500
( Note 3 )
FT-P60
3,500
( Note 3 )
FT-P81X
3,500
( Note 3 )
FT-H35-M2
3,500
( Note 3 )
FT-H20W-M1
1,600
( Note 3 )
FT-H20W-M2
2,600
FT-H20-M1
1,600
( Note 3 )
Sensing range (mm) [Lens on both sides] (Note 2)
Mode
LONG
Fiber
FT-B8
3,500
( Note 3 )
FT-FM2
3,500
( Note 3 )
FT-R80
3,500
( Note 3 )
FT-W8
3,500
( Note 3 )
FT-P80
3,500
( Note 3 )
FT-P60
3,500
( Note 3 )
FT-P81X
3,500
( Note 3 )
FT-H35-M2
3,500
( Note 3 )
FT-H20W-M1
1,600
( Note 3 )
FT-H20W-M2
3,500
( Note 3 )
FT-H20-M1
1,600
( Note 3 )
FT-H13-FM2
3,500
( Note 3 )
Sensing range (mm) [Lens on both sides] (Note 2)
Mode
LONG
Fiber
FT-B8
1,100
FT-FM2
1,200
FT-T80
1,200
FT-W8
900
FT-P80
1,200
FT-P60
650
FT-P81X
1,200
FT-H35-M2
550
FT-H20W-M1
310
FT-H20W-M2
310
FT-H20-M1
550
Sensing range (mm) [Lens on both sides] (Note 2)
Mode
LONG
Fiber
FT-6V
3,500
( Note 3 )
FT-60V
2,800
long (FT-H20W-M1 and FT-H20-M1: 1,600 mm
Description
in. Enables detection of minute objects or small marks.
Distance to focal point: 6
70 C
40 to
158 F
Sensing range (Note 1)
according to
Screw-in depth Distance to focal point
"18.5 mm approx.
7 mm
"27 mm approx.
12 mm
"43 mm approx.
14 mm
40 to
158 F
"0.012 in
approx.
Sensing range (Note 1)
Fiber
Distance to focal point
FD-EG3
FD-EG2
FD-EG1
40 to
158 F
FD-WG4/G4/G6X/G6
Sensing range (Note 1)
"0.004 in
approx.
Fiber
Distance to focal point
FD-EG3
FD-EG2
FD-EG1
4 to
140 F
FD-WG4/G4/G6X/G6
Sensing range (Note 1)
Screw-in depth Distance to focal point
8 mm
13 mm approx.
10 mm
15 mm approx.
40 to
158 F
14 mm
30 mm approx.
FX-301
STD
FAST
S-D
2,500
2,000
1,000
3,500
2,500
1,300
( Note 3 )
3,500
2,500
1,300
( Note 3 )
2,300
1,600
800
2,900
2,000
1,000
3,500
2,500
1,100
( Note 3 )
3,500
1,500
900
( Note 3 )
3,500
2,500
1,100
( Note 3 )
2,000
1,500
750
1,300
900
500
1,300
900
500
1,600
1,100
900
( Note 3 )
STD
FAST
S-D
3,500
3,500
3,500
( Note 3 )
( Note 3 )
( Note 3 )
3,500
3,500
3,500
( Note 3 )
( Note 3 )
( Note 3 )
3,500
3,500
3,500
( Note 3 )
( Note 3 )
( Note 3 )
3,500
3,500
3,500
( Note 3 )
( Note 3 )
( Note 3 )
3,500
3,500
3,500
( Note 3 )
( Note 3 )
( Note 3 )
3,500
3,500
3,500
( Note 3 )
( Note 3 )
( Note 3 )
3,500
3,500
3,500
( Note 3 )
( Note 3 )
( Note 3 )
3,500
3,500
3,500
( Note 3 )
( Note 3 )
( Note 3 )
1,600
1,600
1,500
( Note 3 )
( Note 3 )
3,500
3,000
1,500
( Note 3 )
1,600
1,600
1,600
( Note 3 )
( Note 3 )
( Note 3 )
3,500
3,500
3,500
( Note 3 )
( Note 3 )
( Note 3 )
STD
FAST
S-D
530
400
186
600
440
210
600
440
210
450
330
160
600
440
210
300
200
130
600
440
200
280
200
90
140
100
50
140
100
50
280
200
90
STD
FAST
S-D
2,700
1,800
940
1,450
1,000
490
62.992
in).
1 mm
0.236
0.039 in
Spot diameter
"0.7 mm
"1.2 mm
"2.0 mm
Spot diameter
"0.15 mm approx.
7.5
0.5 mm
"0.2 mm approx.
7.5
0.5 mm
"0.3 mm approx.
7.5
0.5 mm
"0.5 mm approx.
7.5
0.5 mm
Spot diameter
"0.1 mm approx.
7
0.5 mm
"0.15 mm approx.
7
0.5 mm
"0.2 mm approx.
7
0.5 mm
"0.4 mm approx.
7
0.5 mm
Spot diameter
"0.5 mm
"0.8 mm
"3.0 mm
81