Action: Select from
None
Power On – Latch
Power On – Follow
Power Off – Latch
Power Off – Follow
Power Cycle
Power Cycle Once
With AutoPing operational, the main iBoot-G2 page will display the current status of this feature. The
status will be OK to indicate that iBoot-G2 is receiving responses to the ping, or that the fail counter has
not yet been exceeded.
If the fail count has been exceeded, the status will change to FAIL. The Fail Counter will indicate the
number of times the failure has occurred, and the Trigger Counter indicates the number of times the
AutoPing action has been triggered. A counter reset button is provided when logging in with the Admin
password.
Note:
All of the AutoPing Settings require a
reboot of the iBoot-G2, after clicking Save. A
Reboot button will appear at the bottom of the
page. The new settings will not take effect until the
unit is rebooted. Reboot will not affect the power
position of the iBoot-G2. Upon Clicking Reboot,
the Googbye page is displayed with a link to re-
login.
7.5.
Event Scheduling
iBoot-G2 can schedule up to eight reoccurring
power events. Set the starting date and time, plus
the action to be taken and any repeat cycle for
each.
To enable the time scheduling function:
Enter an accessible Network Time Server and check the Enable box. A list of public time servers is
available at
http://www.ntp.org/
Once the time server is active, scheduled events can occur. Up to eight independent scheduled events
can be programmed.
Date: Set the initial date for the event. The format for the date is mm/dd/yyyy.
Time: Set the initial time for the event. The format for the time is hh:mm:ss with hours in 24 hour format.
Repeat: Set the increment of the repeat, if desired. Set the number from 0 to 999 and either Days,
Minutes or Seconds.
Action: Set the event Action; On, Off or Cycle.
V110120E
AutoPing not used
Upon triggering, iBoot-G2 will power on and remain so until changed via the web,
telnet, DxP, etc.
Upon triggering, iBoot-G2 will power on. When the ping response returns, iBoot-G2
will power off.
Upon triggering, iBoot-G2 will power off and remain so until changed via the web,
telnet, DxP, etc.
Upon triggering, iBoot-G2 will power off. When the ping response returns, iBoot-G2
will power on.
Upon triggering, iBoot-G2 will cycle the power. iBoot-G2 will wait the Ping Frequency
x Fail Count; if the response does not return, the power will be recycled again. This
will continue until the ping response returns or Auto Ping is turned off. Make sure your
Auto Ping frequency is longer than the time required to reboot your device.
Upon triggering, iBoot-G2 will cycle power one time. It will not cycle again
automatically until the ping response returns and is lost again.
Set your local time zone relative to GMT.