4th analog expansion adapter
The special registers list for the 4th FX5-4AD-ADP module is shown below.
Special registers
CH1
CH2
SD7380
SD7420
SD7381
SD7421
SD7382
SD7422
SD7383
SD7423
SD7384
SD7424
SD7385
SD7425
SD7386
SD7426
SD7387
SD7427
SD7388
SD7428
SD7389
SD7429
SD7390
SD7430
SD7391
SD7431
SD7392
SD7432
SD7393
SD7433
SD7394
SD7434
SD7395
SD7435
SD7396
SD7436
SD7397
SD7437
SD7402
SD7442
SD7403
SD7443
SD7404
SD7444
SD7405
SD7445
SD7406
SD7446
SD7407
SD7447
SD7408
SD7448
SD7409
SD7449
SD7412
SD7452
SD7413
SD7453
SD7414
SD7454
SD7418
SD7458
SD7419
SD7459
2 FX5-4AD-ADP
80
2.12 List of Special Registers
CH3
CH4
SD7460
SD7500
SD7461
SD7501
SD7462
SD7502
SD7463
SD7503
SD7464
SD7504
SD7465
SD7505
SD7466
SD7506
SD7467
SD7507
SD7468
SD7508
SD7469
SD7509
SD7470
SD7510
SD7471
SD7511
SD7472
SD7512
SD7473
SD7513
SD7474
SD7514
SD7475
SD7515
SD7476
SD7516
SD7477
SD7517
SD7482
SD7522
SD7483
SD7523
SD7484
SD7524
SD7485
SD7525
SD7486
SD7526
SD7487
SD7527
SD7488
SD7528
SD7489
SD7529
SD7492
SD7532
SD7493
SD7533
SD7494
SD7534
SD7498
SD7538
SD7499
SD7539
Name
Digital output value
Digital operation value
Analog input value monitor
Average processing specify
Time Average/Count Average/Moving Average setting
Input range setting
Maximum value
Minimum value
Scaling upper limit value
Scaling lower limit value
Conversion value shift amount
Process alarm upper upper limit value
Process alarm upper lower limit value
Process alarm lower upper limit value
Process alarm lower lower limit value
Rate alarm upper limit value
Rate alarm lower limit value
Rate alarm warning detection period setting
Convergence detection upper limit value
Convergence detection lower limit value
Detection time setting for convergence detection
Deviation detection CH1
Deviation detection CH2
Deviation value for deviation detection between channel
CH setting 1 for deviation detection between channel
CH setting 2 for deviation detection between channel
Offset setting value
Gain setting value
Offset/gain writing enable code
A/D conversion latest alarm code
A/D conversion latest error code
Reference
Page 81
Page 81
Page 81
Page 82
Page 82
Page 83
Page 83
Page 83
Page 84
Page 84
Page 84
Page 85
Page 85
Page 86
Page 86
Page 87
Page 87
Page 88
Page 88
Page 89
Page 89
Page 90
Page 90
Page 90
Page 91
Page 91
Page 92
Page 92
Page 92
Page 93
Page 93

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents