Name
Maximum value/minimum value
reset completed flag

Maximum value reset request

When the "maximum value reset request" is set from OFF to ON, the maximum value is updated to the "digital operation
value".
Setting value
0: OFF
1: ON
For the timing of turning the signal on and off, refer to the following.
Page 68 Maximum value/minimum value reset completed flag
Name
Maximum value reset request

Minimum value reset request

When the "minimum value reset request" is set from OFF to ON, the minimum value is updated to the "digital operation value".
Setting value
0: OFF
1: ON
For the timing of turning the signal on and off, refer to the following.
Page 68 Maximum value/minimum value reset completed flag
Name
Minimum value reset request

Scaling enable/disable setting

Set whether to enable or disable the scaling function.
Setting value
0: OFF
1: ON
For details scaling function, refer to the following.
Page 30 Scaling Function
Name
Scaling enable/disable setting
Connection part
Special relay
CH1
1st adapter
SM6305
2nd adapter
SM6665
3rd adapter
SM7025
4th adapter
SM7385
Setting description
No maximum value reset request
Maximum value reset request
Connection part
Special relay
CH1
1st adapter
SM6306
2nd adapter
SM6666
3rd adapter
SM7026
4th adapter
SM7386
Setting description
No minimum value reset request
Maximum value reset request
Connection part
Special relay
CH1
1st adapter
SM6307
2nd adapter
SM6667
3rd adapter
SM7027
4th adapter
SM7387
Setting description
Scaling function enable
Scaling function disable
Connection part
Special relay
CH1
1st adapter
SM6308
2nd adapter
SM6668
3rd adapter
SM7028
4th adapter
SM7388
CH2
CH3
SM6345
SM6385
SM6705
SM6745
SM7065
SM7105
SM7425
SM7465
CH2
CH3
SM6346
SM6386
SM6706
SM6746
SM7066
SM7106
SM7426
SM7466
CH2
CH3
SM6347
SM6387
SM6707
SM6747
SM7067
SM7107
SM7427
SM7467
CH2
CH3
SM6348
SM6388
SM6708
SM6748
SM7068
SM7108
SM7428
SM7468
2.11 Detail of Special Relays
CH4
SM6425
SM6785
SM7145
SM7505
Default value
R/W
0: OFF
R/W
CH4
SM6426
SM6786
SM7146
SM7506
Default value
R/W
0: OFF
R/W
CH4
SM6427
SM6787
SM7147
SM7507
Default value
R/W
1: ON
R/W
CH4
SM6428
SM6788
SM7148
SM7508
2 FX5-4AD-ADP
69
2

Advertisement

Table of Contents

   Related Content for Mitsubishi Electric MELSEC iQ-F FX5

Comments to this Manuals

Symbols: 0
Latest comments: